Induced Draft (ID) Fan for Bogie Hearth Furnaces

The ID fan on a bogie hearth furnace draws flue gas from a batch cycle that may run from cold to over 1,000°C and back over many hours. Its gas temperature follows the cycle, and during forced cooling it may handle large quantities of hot air. Covering this changing duty decides the design.

Send your duty pointCall +91 91766 67102
250 to 400°C after dilution, varying with the cycleGas temperature, normal
0.57 kg/m³Gas density at 350°C
Backward inclined plate bladesBlade form

How bogie hearth furnaces work

A bogie hearth or car bottom furnace is a large batch furnace whose hearth is a refractory-lined bogie that runs out on rails for loading heavy castings, forgings, fabrications or coils. It is used for annealing, normalising, stress relieving, hardening and tempering, typically between about 550 and 1,100°C. Burners on the side walls, usually high velocity gas or oil burners, fire into the chamber, often with a programmed cycle of ramp, soak and controlled cooling lasting many hours. Flue gas leaves through roof or sidewall flues, sometimes through a recuperator, and the temperature at the flue follows the cycle. Controlled cooling is often done by running the combustion air blower with burners off, or with separate cooling air fans.

Where the ID fan sits

  1. Furnace chamber
  2. Roof or sidewall flue
  3. Dilution air inlet
  4. Recuperator (if fitted)
  5. ID fan
  6. Stack

The fan sits at the end of the flue, after any recuperator, and usually beside the furnace. Gas leaving the furnace ranges from a few hundred degrees early in the cycle to over 1,000°C at soak, so dilution air is added to keep the fan at about 300 to 400°C. During forced cooling the fan exhausts large volumes of air blown through the chamber, at decreasing temperature. Suction is modest, typically 50 to 150 mmWC.

Gas at the ID fan

Gas temperature, normal250 to 400°C after dilution, varying with the cycle
Maximum or upset500 to 600°C if dilution air is short at soak
Dust at the fanLow; scale and refractory dust from the bogie seals
Cycle patternRamp, soak and cooling over many hours, with cold starts
Cooling phaseLarge volume of hot air from forced cooling
Density at the design temperatureAbout 0.57 kg/m³ at 350°C, 47% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for bogie hearth furnaces

Blade formBackward inclined plate blades, robust for thermal cycling
Material of constructionHeat-resisting steel impeller where gas exceeds about 400°C; mild steel casing with insulation
Drive and arrangementDirect coupled, with sliding casing supports for repeated thermal cycles
Bearings and coolingCooling disc and heat shield
Flow controlVariable speed drive on furnace pressure through all cycle phases
Also specifiedDilution air damper on fan inlet temperature; slow turning after shutdown

What this ID fan has to cope with

Thermal cycling fatigue

A bogie hearth fan heats and cools with every batch, sometimes daily. Repeated expansion and contraction cracks welds at the impeller hub and blade roots and loosens fits. Impeller design for cyclic thermal stress, generous fillet welds, and a shaft fit that stays tight at temperature extend fan life.

Changing flow through the cycle

Flue gas flow is low at soak and high during heat-up and forced cooling. A fan sized for the peak cooling flow runs throttled most of the cycle. Variable speed control on furnace pressure handles the range and reduces power. The control must also be stable at the low soak flows, where a fan with a flat curve tends to hunt and upset furnace pressure.

Air ingress at the bogie seals

The seals between bogie and furnace walls wear and leak. If the fan pulls too much suction, cold air enters around the load and affects temperature uniformity, which matters for heat treatment quality. Holding a small positive pressure protects uniformity. The seals should also be inspected and replaced at regular intervals, since no fan control can make up for a badly worn seal.

Energy and control

A bogie hearth furnace spends most of its cycle at soak, when firing and flue gas flow are low. A variable speed ID fan holding furnace pressure cuts power during the long soak and avoids drawing cold air through the bogie seals, which improves uniformity as well as fuel use.

ID fan and FD fan in bogie hearth furnaces

ID fanFD fan
PositionEnd of flue, after dilutionBeside the furnace, feeding the burners
What it handlesFlue gas, then cooling airAmbient air for firing and cooling
Temperature at the fan250 to 400°C, varying through the cycleAmbient
Main design concernThermal cycling fatigueTwo duty points, firing and cooling
ControlFurnace pressure through the cycleHeader pressure, then cooling rate

See also the Forced Draft (FD) Fan for bogie hearth furnaces.

Questions buyers ask

Does a bogie hearth furnace need an ID fan?

Many bogie hearth furnaces work with a natural draft flue and damper. An induced draft fan is used when a recuperator is fitted, when the flue is long, or when tight furnace pressure control is needed for temperature uniformity in heat treatment. The fan also handles the forced cooling air on many designs.

What temperature does a bogie hearth furnace ID fan see?

It follows the cycle. Flue gas at soak can exceed 1,000°C, so dilution air brings it to about 300 to 400°C at the fan. The impeller and bearings must handle the highest temperature reached if dilution is short. During forced cooling the fan handles a much larger volume of air at falling temperature, which sets the maximum flow.

How does pressure control affect heat treatment uniformity?

If the furnace runs under suction, cold air enters through bogie seals and door gaps and creates cold spots around the load. Holding a small positive pressure with ID fan control keeps the furnace atmosphere even and helps meet uniformity requirements. It also reduces fuel use and scale on the load.

Information needed to quote an ID fan for bogie hearth furnaces

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Heat treatment cycle. Maximum temperature, ramp rates, soak time and forced cooling method.
  6. Flue arrangement. Dilution air, recuperator and the flue gas temperature at furnace outlet.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for bogie hearth furnaces: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote