Home › Applications › ID Fan › Ammonia Plant Primary Reformers

Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Ammonia Plant Primary Reformers

The ID fan on an ammonia plant primary reformer is one of the plant's critical machines: it pulls flue gas through a convection section that also heats process air and steam, so a fan trip upsets the whole front end. Reliability, drive choice and the steam balance decide its design more than the gas condition, which is clean and moderate in temperature.

Send your duty pointCall +91 91766 67102
140 to 180°C after the air preheaterGas temperature, normal
0.82 kg/m³Gas density at 160°C
Backward curved or aerofoilBlade form

How ammonia plant primary reformers work

In an ammonia plant the primary reformer converts desulphurised natural gas or naphtha and steam to synthesis gas in catalyst tubes, with the process gas leaving at about 780 to 830°C. Reforming is completed in the secondary reformer, where process air is added to supply the nitrogen. The primary reformer is a large top-fired or side-fired box burning natural gas, often with purge gas from the synthesis loop. Flue gas leaves the radiant section near 1,000°C and passes a long convection section with coils for mixed feed preheat, process air preheat, steam superheat, feed and boiler water heating, and combustion air preheat. An ID fan draws the gas to the stack at 140 to 180°C. In many older plants the ID and FD fans are driven by steam turbines as part of the plant steam balance.

Where the ID fan sits

  1. Radiant box
  2. Convection coils: process air, steam, feed
  3. Combustion air preheater
  4. ID fan
  5. Stack

The fan is at the cold end of the convection section, at grade, after the combustion air preheater. Upstream are many coil banks, each adding resistance, so the total suction is typically 200 to 350 mmWC. The firebox is held at a small negative draft, a few millimetres of water at the arch. The ID fan is often turbine-driven, using steam from the plant's own boilers, with a motor-driven or second turbine fan in some plants for redundancy.

Gas at the ID fan

Gas temperature, normal140 to 180°C after the air preheater
Maximum or upset250 to 350°C with the preheater bypassed
Dust at the fanNegligible; refractory dust after repairs
Moisture and dew pointWater dew point 55 to 65°C from natural gas and purge gas firing
Corrosive speciesVery little sulphur; trace ammonia from purge gas firing
Density at the design temperatureAbout 0.82 kg/m³ at 160°C, 68% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for ammonia plant primary reformers

Blade formBackward curved or aerofoil, for efficiency on a large clean flow
Material of constructionMild steel or boiler plate rated for the bypass temperature
Drive and arrangementSteam turbine or motor, direct coupled; double inlet on large plants
Bearings and coolingOil-lubricated sleeve bearings with a lube oil console, temperature and vibration monitoring
Flow controlTurbine speed governor or variable speed drive on firebox draft
Also specifiedDesign for the turbine's overspeed, API 673 or equivalent, and hot standby where fitted

What this ID fan has to cope with

A fan trip trips the front end

Losing the ID fan forces the reformer burners off, and with them the steam generation and process air preheat in the convection section. The whole front end, and often the ammonia loop, goes down. Reliable lube oil systems, governor maintenance and careful trip settings avoid a large production loss from a minor fault.

Steam turbine drive and speed range

A steam turbine drive gives speed control at no extra cost, but the fan must be designed and balanced for the full speed range, including turbine overspeed trip speed. Critical speeds must lie outside the operating range, and the rotor is checked for stress at the trip speed.

Throughput increases beyond the fan

Many ammonia plants have been uprated in capacity over the years. The ID fan, sized for the original duty, often becomes the limit. A new impeller, a higher speed or a replacement fan, checked against the existing casing, foundation and drive, can release the extra capacity.

Energy and control

Ammonia plants run continuously at high load, and the primary reformer ID fan is a large power consumer, whether through electrical power or steam. With a steam turbine drive, fan efficiency affects the steam balance; with a motor drive, a variable speed drive saves power at reduced rates. A more efficient impeller on an uprated plant can lower both power and steam use.

ID fan and FD fan in ammonia plant primary reformers

ID fanFD fan
PositionEnd of convection section, before stackBefore the combustion air preheater
What it handlesClean flue gasAmbient air
Temperature at the fan140 to 180°CAmbient
Main design concernReliability and turbine driveAir distribution and gas turbine standby
ControlFirebox draftAir flow with oxygen trim

See also the Forced Draft (FD) Fan for ammonia plant primary reformers.

Questions buyers ask

Why are ammonia reformer ID fans driven by steam turbines?

Ammonia plants produce surplus high-pressure steam from waste heat. Using steam turbines to drive large machines such as the reformer ID and FD fans fits into the plant's steam balance and gives variable speed. Some plants now use motors with variable speed drives instead, depending on the steam balance and reliability needs.

What happens when the primary reformer ID fan trips in an ammonia plant?

The reformer burners trip because the firebox can no longer be held under draft. With them, the convection section's steam generation and process air preheat are lost, so the front end of the ammonia plant shuts down. Restarting takes several hours, which is why fan reliability is critical.

Can the ID fan be upgraded when an ammonia plant is uprated?

Often yes. A new impeller designed for the higher flow and pressure, a speed increase within the drive's capability, or a replacement fan on the existing foundation can be used. The casing, shaft, bearings, drive and foundation must all be checked for the new duty.

Information needed to quote an ID fan for ammonia plant primary reformers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Drive. Steam turbine or motor, speed range and the turbine overspeed trip speed.
  6. Uprating. Original design duty, present operating point and the target duty after uprating.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for ammonia plant primary reformers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.