Induced Draft (ID) Fan for Activated Carbon Regeneration Furnaces

The ID fan on an activated carbon regeneration furnace draws the off-gas through the thermal oxidiser, quench and scrubber. What the carbon adsorbed decides its design: chlorinated organics from water treatment leave HCl in a saturated gas, so corrosion resistance matters more than temperature.

Send your duty pointCall +91 91766 67102
60 to 80°C, saturated after the scrubberGas temperature, normal
1.03 kg/m³Gas density at 70°C
Backward inclined or radialBlade form

How activated carbon regeneration furnaces work

Spent granular activated carbon from water treatment, sugar decolourising, solvent recovery or gold recovery circuits is dewatered and fed to a rotary kiln or multiple hearth furnace. The carbon is dried, the adsorbed organics are desorbed and pyrolysed, and the char left in the pores is gasified with steam at about 750 to 900°C. Many smaller units, especially in gold plants, are indirectly fired, with the burner heating the outside of the tube. The off-gas carries steam, organic vapours and fine carbon to a thermal oxidiser at 850 to 1,100°C, then a quench, a wet scrubber where acid gases are present, and the ID fan. The FD fan provides combustion air for the furnace and oxidiser burners.

Where the ID fan sits

  1. Regeneration kiln or hearth
  2. Thermal oxidiser
  3. Quench
  4. Wet scrubber
  5. Mist eliminator
  6. ID fan
  7. Stack

The fan sits after the scrubber and mist eliminator, at the cold end of the system. It must overcome the furnace, the oxidiser, the quench, the packed or venturi scrubber and the droplet separator, typically 250 to 450 mmWC when a venturi is used. Placing it at the wet end means it handles cool, saturated gas of small volume rather than hot oxidiser gas, at the cost of a wet, sometimes acidic duty.

Gas at the ID fan

Gas temperature, normal60 to 80°C, saturated after the scrubber
Maximum or upsetUp to 200°C or more if quench water fails, until the trip acts
Dust at the fanLittle; fine carbon and salt in droplet carry-over
Moisture and dew pointSaturated gas with free droplets; condensate collects in the casing
Corrosive speciesHCl and SO₂ traces where the spent carbon held chlorinated or sulphur compounds; chlorides from scrubber recycle
Density at the design temperatureAbout 1.03 kg/m³ at 70°C, 86% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for activated carbon regeneration furnaces

Blade formBackward inclined or radial, plate blades that shed droplets
Material of constructionSS 316 or 316L wetted parts for chloride duty; FRP for strongly acidic gas on smaller fans
Drive and arrangementBelt driven or direct coupled, arrangement 9 or 8
Bearings and coolingBearings outside the gas stream with a shaft seal against wet gas
Flow controlVariable speed drive on furnace or oxidiser draft
Also specifiedCasing drain at the lowest point, a high-temperature trip, and a flushing connection for salt deposits

What this ID fan has to cope with

Chloride corrosion of wetted parts

Spent carbon from municipal water or chemical plants often carries chlorinated organics. After oxidation the chlorine appears as HCl, which the scrubber removes only partly. The fan casing and wheel, constantly wet, pit and crack in ordinary steel. SS 316L or FRP, with welds pickled and the drain kept clear, gives a long life.

Quench failure

If the quench water supply fails, gas at oxidiser temperature reaches an FRP or lightly built stainless fan within seconds. A temperature trip on the scrubber inlet that stops the burner and opens an emergency vent upstream protects the fan, and the fan material is chosen with this event in mind.

Salt and carbon deposits on the blades

Droplets that pass the mist eliminator carry dissolved salts and carbon fines, which dry on the blades and build up unevenly. A water flushing nozzle in the casing, used on a schedule, and a well-maintained mist eliminator keep the wheel clean and in balance between shutdowns.

Energy and control

Regeneration furnaces often run in campaigns, processing stockpiles of spent carbon at varying feed rates. A variable speed drive on draft lets the fan follow the furnace through start-up, partial feed and hot standby, which saves much of the power a throttled fan uses. Lower pressure drop across a well-maintained scrubber and mist eliminator also reduces fan energy directly.

ID fan and FD fan in activated carbon regeneration furnaces

ID fanFD fan
PositionAfter the quench, scrubber and mist eliminatorAt the furnace and oxidiser burners
What it handlesSaturated, sometimes acidic gasClean ambient air
Temperature at the fan60 to 80°CAmbient
Main design concernChloride corrosion and quench failureAir to match varying organic load
ControlFurnace or oxidiser draftBurner ratio and oxidiser oxygen

See also the Forced Draft (FD) Fan for activated carbon regeneration furnaces.

Questions buyers ask

What material is used for the ID fan of a carbon regeneration kiln?

After a wet scrubber the gas is saturated and may contain HCl, so wetted parts are usually SS 316L. FRP is used on smaller fans with strongly acidic gas. A dry system with a bag filter and gas above the dew point can use mild steel.

Does a gold plant carbon regeneration kiln need an ID fan?

Many small indirectly fired kilns vent the tube off-gas and the burner flue separately, sometimes by natural draft. An ID fan is needed when the off-gas is treated in an oxidiser or scrubber, or when steady draft is required for the carbon quality. The fan is then sized on the treated gas, not on the kiln alone.

How do I protect the ID fan if the quench water fails?

Fit a temperature trip at the scrubber inlet that stops the burners and opens an emergency vent ahead of the quench. The fan is then exposed to hot gas only for a few seconds, and its materials, especially for an FRP fan, are checked for that short event.

Information needed to quote an ID fan for activated carbon regeneration furnaces

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Spent carbon source. What the carbon has adsorbed, and whether chlorinated or sulphur organics are present.
  6. Scrubber chemistry. Scrubbing liquor, its pH and chloride level, and the gas condition after the mist eliminator.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for activated carbon regeneration furnaces: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote