13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › ID Fan › Activated Carbon Rotary Kilns

Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Activated Carbon Rotary Kilns

The ID fan on an activated carbon rotary kiln draws gas from the kiln through the afterburner, waste heat boiler and dust collector. It sets the kiln hood pressure, and that pressure controls air leakage into the activation zone, which burns product. Tight, stable draft is the design priority.

Send your duty pointCall +91 91766 67102
180 to 230°C after the waste heat boilerGas temperature, normal
0.73 kg/m³Gas density at 210°C
Backward curved after a bag filterBlade form

How activated carbon rotary kilns work

Carbonised char, most often from coconut shell, is activated in a rotary kiln at about 850 to 950°C with steam injected along the bed. The steam reacts with the carbon to open the pore structure, releasing a lean fuel gas rich in carbon monoxide and hydrogen. Burnt-off carbon is typically 40 to 60% of the char fed. The kiln off-gas passes to a post-combustion chamber where air burns the CO and hydrogen, raising the gas to 900 to 1,100°C, then to a waste heat boiler that raises the process steam. After the boiler the gas, still humid and carrying carbon fines, goes through a cyclone and bag filter or wet scrubber to the ID fan. The FD fan supplies burner and post-combustion air.

Where the ID fan sits

  1. Rotary kiln
  2. Post-combustion chamber
  3. Waste heat boiler
  4. Cyclone
  5. Bag filter or scrubber
  6. ID fan
  7. Stack

The fan sits at the cold end of the gas train, after the waste heat boiler and the final collector. Upstream losses include the kiln, the afterburner, the boiler passes and the collector, typically 150 to 300 mmWC in total. The fan holds the kiln feed hood at a very small suction, often only 1 to 3 mmWC, because any extra draft pulls air through the rotary seals into the kiln, where oxygen burns activated carbon instead of steam developing pores.

Gas at the ID fan

Gas temperature, normal180 to 230°C after the waste heat boiler
Maximum or upset350°C or more with boiler tube fouling or a boiler bypass
Dust at the fanFine, light carbon and ash; low after a bag filter, near saturated droplets after a scrubber
Moisture and dew pointSteam from activation and hydrogen combustion gives 25 to 40% water vapour by volume and a water dew point of about 65 to 75°C
Corrosive speciesLow sulphur from shell char; chlorides from some feedstocks can attack wet surfaces
Density at the design temperatureAbout 0.73 kg/m³ at 210°C, 61% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for activated carbon rotary kilns

Blade formBackward curved after a bag filter; radial or backward inclined with drain holes after a wet scrubber
Material of constructionMild steel for dry gas above the dew point; SS 304 or 316 wetted parts after a scrubber
Drive and arrangementDirect coupled, arrangement 8, with a variable speed drive
Bearings and coolingPedestal bearings with a shaft cooling disc for upset temperatures
Flow controlVariable speed drive on kiln hood pressure, with fast response
Also specifiedCasing drain, insulated casing to stay above the dew point, and an inlet damper for start-up

What this ID fan has to cope with

Air ingress through draft swings

If the ID fan responds slowly or the damper hunts, hood suction swings, and every surge pulls air through the kiln seals. The burn-off rises and yield falls, often without anyone tracing it back to the fan. A variable speed drive tuned for fast, small corrections and a pressure tapping that is not plugged by fines keep the draft tight.

Condensation on a humid gas

With water vapour at a third of the gas volume, any part of the casing or duct below about 75°C wets out. Carbon fines then paste onto the blades. The fan casing and ducts are insulated, the gas leaves the boiler well above the dew point, and the fan is run to purge warm before shutdown.

Carbon fires in the collector

Hot carbon fines that escape the afterburner can smoulder in a bag filter hopper and reach the fan as sparks. A spark arrestor or settling chamber before the filter, a temperature watch on the hopper and a fan casing with an access door help contain and clear any deposit fire.

Energy and control

Activation kilns usually run continuously for months, so the ID fan runs at a steady point most of the time. The saving lies in sizing that point correctly, because many fans are oversized and throttled to hold the small hood suction. A variable speed drive brings the fan down to the real duty and improves draft control at the same time. Keeping the waste heat boiler clean lowers both gas volume and resistance.

ID fan and FD fan in activated carbon rotary kilns

ID fanFD fan
PositionAfter the waste heat boiler and collectorAt the kiln burner and afterburner
What it handlesHumid combustion gas with carbon finesClean ambient air
Temperature at the fan180 to 230°CAmbient
Main design concernTight hood draft and condensationComplete burn-out of off-gas
ControlKiln hood pressureAfterburner temperature and oxygen

See also the Forced Draft (FD) Fan for activated carbon rotary kilns.

Questions buyers ask

Why does the kiln draft matter so much in activated carbon production?

The activation reaction relies on steam, not air. Extra draft at the kiln pulls air in through the seals, and the oxygen burns carbon that should have become product. Holding a small, steady suction with the ID fan reduces air ingress and protects yield and iodine number.

What material should the ID fan be for an activated carbon kiln with a wet scrubber?

After a wet scrubber the gas is saturated and often slightly acidic, so the wetted parts are usually SS 304 or 316. If the gas is reheated above its dew point, or a bag filter is used instead, mild steel with an insulated casing is normally sufficient.

Is the ID fan of an activated carbon kiln the same as a boiler ID fan?

It does a similar job, because the waste heat boiler sits in the gas path. The difference is the very humid gas from steam activation, the light carbon fines and the need for tight hood pressure control, which a standard boiler ID fan specification does not cover.

Information needed to quote an ID fan for activated carbon rotary kilns

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Kiln operation. Kiln throughput, steam injection rate and the target hood pressure.
  6. Gas cleaning. Whether the fan follows a bag filter or a wet scrubber, and the gas temperature at its inlet.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for activated carbon rotary kilns: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote