13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Steel Reheating Furnaces

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Steel Reheating Furnaces

The FD fan on a reheating furnace is the combustion air fan. It supplies air to the burners, usually through a recuperator or regenerators that preheat it. The fan nearly always handles ambient air, and its pressure depends on the burner type and the heat recovery equipment in the air path.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How steel reheating furnaces work

Steel reheating furnaces heat billets, blooms and slabs to about 1,100 to 1,250°C before rolling. The main types are pusher furnaces, where the stock is pushed along skids, walking beam and walking hearth furnaces, where it is lifted and stepped forward, and batch or rotary hearth furnaces for special products. Fuels range from furnace oil and producer gas in re-rolling mills to natural gas and mixed works gases in integrated plants. Heat recovery varies just as widely: none at all, a metallic recuperator, regenerative burners, or a waste heat boiler. The furnace type, fuel and recovery method decide the temperature at the ID fan and the pressure the FD fan must deliver, and in some smaller furnaces a chimney alone provides the draft.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Recuperator or reversing valves
  4. Air main
  5. Zone valves
  6. Burners

The fan draws ambient air and delivers it to the recuperator or, on regenerative furnaces, to the reversing valves and regenerator beds. On simple oil-fired furnaces the air may go straight to the burners. The fan pressure covers burner nozzle pressure, recovery equipment and distribution, from about 300 mmWC on simple furnaces to 700 to 1,000 mmWC on high velocity or regenerative firing.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after preheating300 to 550°C after a recuperator; up to about 1,000°C after regenerators
DustClean, filtered air
Pressure at the fan outletAbout 300 to 1,000 mmWC
TurndownWide, following mill delays and zone firing
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for steel reheating furnaces

Blade formBackward curved, at a tip speed matched to the pressure
Material of constructionMild steel; high strength plate on high pressure fans
Drive and arrangementDirect coupled at two-pole speed for high pressure duties
Bearings and coolingStandard bearings, no cooling
Flow controlVariable speed drive on air main pressure
Also specifiedInlet silencer and filter; standby fan on continuous mills

What this FD fan has to cope with

Insufficient pressure after burner changes

Upgrading from low pressure oil burners to high velocity gas burners, or adding regenerative burners, raises the pressure needed at the fan considerably. An old fan kept in service then cannot deliver full air at full firing, and the furnace runs short of air in the hottest zones. The fan must be rechecked whenever burners change.

Recuperator overheating on air failure

Losing combustion air while the furnace is hot leaves a metallic recuperator with hot flue gas on one side and no cooling air on the other. Tubes can distort or crack within minutes. Low air flow interlocks, dilution air and a reliable fan, with a standby on continuous mills, protect it.

Noise in the mill bay

High pressure combustion air fans running at two-pole speed are loud, mainly at the inlet. Where several furnaces share a bay the noise adds up. Inlet silencers, acoustic lagging on the casing and a quiet blade selection are commonly specified on reheating furnaces built close to the rolling mill floor.

Energy and control

The combustion air fan runs whenever the furnace is hot. Variable speed control on air main pressure saves power at the low firing rates that follow mill delays. Correct air to fuel ratio across all zones has the larger effect on fuel cost, and the fan must give the ratio control enough pressure to work.

ID fan and FD fan in steel reheating furnaces

ID fanFD fan
PositionEnd of heat recovery, before chimneyBefore recuperator or regenerators
What it handlesFlue gas, low dustAmbient air
Temperature at the fan150 to 500°C by furnace typeAmbient
Main design concernMatching material to the recovery schemePressure for the burner type
ControlFurnace pressureAir main pressure and air to fuel ratio

See also the Induced Draft (ID) Fan for steel reheating furnaces.

Questions buyers ask

Is the FD fan on a reheating furnace the combustion air blower?

Yes. On a reheating furnace the FD fan and the combustion air blower are the same machine. The forced draft fan supplies all the air for combustion, preheated through a recuperator or regenerators where fitted, and on oil-fired furnaces it may also provide the atomising air for low pressure burners.

How much pressure does a reheating furnace combustion air fan need?

It depends on the burners and the heat recovery. Simple oil burners with no recuperator may need 300 to 500 mmWC at the fan; furnaces with recuperators and high velocity burners, or regenerative systems with their reversing valves and ceramic beds, often need 700 to 1,000 mmWC or more.

Does the FD fan see hot air on a reheating furnace?

Normally no. The fan handles ambient air and pushes it through the recuperator or regenerators, so the hot air is downstream of it. Hot air fans placed after the recuperator are rare, because they would be larger, need heat-resisting construction and cost more to run for the same air mass.

Information needed to quote an FD fan for steel reheating furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner data. Burner type, number per zone and air pressure needed at full firing.
  6. Air path losses. Pressure drop through the recuperator, reversing valves or regenerators.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for steel reheating furnaces: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote