Home › Applications › FD Fan › Magnesite Dead Burning Kilns

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Magnesite Dead Burning Kilns

The FD fans on a magnesite dead burning kiln are the cooler fans. They blow ambient air through the hot sintered magnesia on a grate cooler, cooling the product and returning hot secondary air to the kiln. They handle cold air, but they must push it through a dense bed of very hot grains, compartment by compartment.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How magnesite dead burning kilns work

Magnesite, magnesium carbonate, is dead-burnt to dense sintered magnesia for refractories at about 1,700 to 2,000°C. Many plants use two stages: the ore is first calcined to caustic magnesia at 800 to 1,000°C, then ground, briquetted and dead-burnt in a high temperature shaft kiln or rotary kiln. Single-stage rotary kilns burn raw magnesite directly. Furnace oil, petcoke, coal or producer gas is fired with hot secondary air from a grate or rotary cooler. Because the burning temperature is very high, the kiln exit gas is hot, often 700 to 1,000°C on a long rotary kiln without a preheater. The gas carries fine MgO dust and is cooled by heat recovery, air dilution or water spray before a bag filter and the ID fan.

Where the FD fan sits

  1. Inlet filter
  2. Cooler FD fans
  3. Undergrate compartments
  4. Sintered magnesia bed
  5. Kiln hood
  6. Kiln

The fans are arranged along the grate cooler, each feeding one or more undergrate compartments. Air passes up through the bed of sintered magnesia, discharged from the kiln at about 1,400 to 1,600°C. The hot air from the first compartments goes to the kiln as secondary air; the air from the later compartments is vented. Pressures are highest under the hot end, typically 500 to 900 mmWC, and lower towards the cold end. A separate primary air fan supplies the burner.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the bedUp to about 1,000°C in the first compartments, downstream of the fan
DustMagnesia dust around the cooler; filtered intakes advised
Pressure at the fan outletTypically 500 to 900 mmWC at the hot end, less at the cold end
VariationBed depth and grain size change with kiln output
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for magnesite dead burning kilns

Blade formBackward curved, with a steep curve for changing bed resistance
Material of constructionMild steel
Drive and arrangementDirect coupled, one fan per compartment or group
Bearings and coolingStandard bearings
Flow controlVariable speed drive or inlet vanes on each fan, on compartment air flow
Also specifiedInlet filters, flow measurement per fan, non-return dampers

What this FD fan has to cope with

Red river on the grate

Fine material segregates and forms a dense, hot stream along the cooler that the air cannot penetrate. The hot-end fans need pressure margin and individual control so more air can be forced into the dense zone.

Grate overheating

If a hot-end fan trips, the grate plates under it overheat in minutes. A standby or interlocked fan arrangement and alarms on compartment pressure protect the grate.

Hood pressure balance

The cooler fans push air into the hood while the kiln ID fan and cooler vent fan draw it away. Without coordinated control the hood swings and blows dust or draws cold air. Air flow control on the cooler fans and pressure control on the ID fan keep the balance.

Energy and control

Cooler fans together use significant power, and they run with the kiln. Speed control per fan, set on air flow, avoids the losses of throttled dampers. The air from the hot compartments is recovered heat, so getting the split right between secondary air and vent air reduces fuel use, which is high on dead burning kilns.

ID fan and FD fan in magnesite dead burning kilns

ID fanFD fan
PositionAfter gas cooling and the bag filterUnder the grate cooler compartments
What it handlesCooled kiln gas, often with dilution airAmbient cooling air
Temperature at the fan200 to 250°C, upsets to 450°CAmbient
Main design concernCooling failure and hot upsetsPressure through hot, dense beds
ControlKiln hood pressureCompartment air flow

See also the Induced Draft (ID) Fan for magnesite dead burning kilns.

Questions buyers ask

Which fans are the FD fans on a magnesite kiln?

The cooler fans supply most of the combustion air as hot secondary air, so they are the main forced draft fans on a magnesite dead burning kiln. A smaller primary air fan supplies the burner.

What pressure do grate cooler fans need?

Typically 500 to 900 mmWC under the hot end, where the bed is dense and hot, and less towards the cold end. Each fan is selected for its own compartment.

Why does each cooler compartment have its own fan?

The bed resistance and cooling need differ along the cooler. Separate fans or controlled groups let the air be set for each zone, giving better heat recovery and protecting the grate.

Information needed to quote an FD fan for magnesite dead burning kilns

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Cooler. Cooler type, number of compartments, grate area and product rate.
  6. Air per compartment. Air flow and pressure for each compartment or group.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for magnesite dead burning kilns: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote