13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Gas Fired Hot Air Generators

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Gas Fired Hot Air Generators

The FD fan on a gas fired hot air generator is the process air fan that pushes ambient air past the line burner into the dryer, or the combustion air fan of a packaged burner. On line burners the fan must hold the air velocity across the burner profile within a narrow band, and that decides its selection and control.

Send your duty pointCall +91 91766 67102
Ambient, 20 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved or aerofoilBlade form

How gas fired hot air generators work

Gas fired hot air generators burn natural gas, LPG or biogas, and because the combustion products are clean they are usually direct fired, even for food. A line burner, also called a duct burner, sits inside the process air duct and fires directly into the moving air stream; or a packaged burner fires into a small combustion chamber and the flame gas mixes with process air. Typical uses are grain, spice, pasta, snack, tea and milk powder dryers, and paint and coating ovens. The air leaves at 80 to 250°C with a little added water vapour and CO₂. The dryer exhaust fan is part of the dryer rather than the generator, so this page covers the FD fan that supplies the process and combustion air.

Where the FD fan sits

  1. Inlet filter
  2. FD (process air) fan
  3. Line burner profile
  4. Mixing section
  5. Dryer

The fan sits upstream of the burner, on cold filtered air, and pushes it through the burner profile plate and the dryer. Placing it before the burner keeps it at ambient temperature, small and simple. The profile plate around the line burner is sized for a set air velocity past the flame, typically 10 to 15 m/s, and the fan must hold that velocity as the dryer resistance and filters change.

Air at the FD fan

Air temperature at the fanAmbient, 20 to 45°C
Air after the burner80 to 250°C, downstream of the fan
DustFiltered air; the product sees whatever the fan delivers
Pressure at the fan outletSet by the filters, burner profile and dryer, often 100 to 250 mmWC
Burner conditionAir velocity across the profile held within the burner maker's range
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for gas fired hot air generators

Blade formBackward curved or aerofoil, for efficiency on clean air
Material of constructionMild steel with food-grade coating, or stainless steel for food dryers
Drive and arrangementDirect coupled or belt driven
Bearings and coolingStandard bearings outside the air stream; no cooling needed
Flow controlVariable speed drive holding air flow or profile pressure drop
Also specifiedAir flow proving switch for the burner safety system, inlet filter and flexible connections

What this FD fan has to cope with

Profile velocity out of range

A line burner is designed for a narrow band of air velocity. Too little air and the flame lengthens and overheats the burner; too much and it lifts off or produces CO. As filters load and dryer resistance changes, a fixed speed fan drifts out of the band. Speed control holding profile pressure drop keeps the burner in its window.

Purge and air proving

Gas safety codes require proven air flow and a pre-purge before ignition. The fan must deliver the purge volume through the whole dryer, and an air flow or pressure switch must prove it. A fan selected without considering purge can leave the burner unable to light reliably.

Combustion products in food

Direct gas firing adds water vapour, CO₂ and small amounts of NOx to the drying air. Most food dryers accept this with clean, well-adjusted low NOx burners. Keeping the fan delivering the design air flow, so the burner never runs rich, keeps CO and NOx low in the product air.

Energy and control

The process air fan moves all the drying air, so it is the main electrical load of a gas fired generator and runs for the whole production period. A high efficiency backward curved or aerofoil wheel and a variable speed drive pay back quickly. Recirculating part of the dryer exhaust to the fan inlet, where humidity allows, raises the inlet temperature and reduces gas consumption; the fan is then selected at the mixed temperature.

Questions buyers ask

Can a gas fired hot air generator be used directly for food drying?

Yes, in most cases. Natural gas and LPG burn cleanly, and direct gas fired dryers are common for grain, spices, pasta, snacks and tea. The burner must be well adjusted and the process air fan must hold the design air flow so the flame stays clean.

What air velocity does a line burner need from the process air fan?

Typically 10 to 15 m/s across the burner profile, though each burner maker gives its own range. The fan is selected to hold that velocity at all dryer loads, usually with a speed drive controlled on the pressure drop across the profile plate, so the flame stays stable as filters load and dryer resistance changes.

Does a gas fired hot air generator need an ID fan?

Not as part of the generator. The combustion products go into the dryer with the process air, and the dryer exhaust fan handles them with the moisture from the product. That exhaust fan is selected as a dryer fan, on the exhaust temperature, humidity and product dust.

Information needed to quote an FD fan for gas fired hot air generators

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner. Line burner or packaged burner, firing range and the required profile velocity or wind box pressure.
  6. Dryer. Product, dryer type and the air temperature and volume required.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for gas fired hot air generators: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote