Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Fluidised Bed Hot Air Generators

The FD fan on a fluidised bed hot air generator is the fluidising air fan. It pushes ambient air through the distributor nozzles to hold the sand bed fluidised, at pressures far above any grate or burner fan. A separate dilution air fan often feeds the mixing chamber. High pressure with a stable curve near minimum fluidising flow decides the FD fan design.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
High pressure backward curved or radial bladed wheelBlade form

How fluidised bed hot air generators work

A fluidised bed hot air generator burns crushed coal, lignite, petcoke blends or biomass in a bed of sand at 800 to 900°C, fluidised by high pressure air through a nozzle distributor. It suits low grade, high-ash or high-moisture fuels that a grate handles poorly, and supplies large ceramic spray dryers, mineral and clay dryers and some kiln preheating duties. The gas leaving the freeboard passes a hot cyclone that returns or removes coarse ash and bed fines, then enters a mixing chamber where dilution air brings it to the dryer inlet temperature, typically 400 to 650°C. Limestone is often added to the bed to capture sulphur from lignite and coal. The dryer exhaust goes through cyclones and a bag filter or scrubber to the exhaust fan.

Where the FD fan sits

  1. Inlet silencer
  2. FD (fluidising air) fan
  3. Air box
  4. Distributor nozzles
  5. Fluidised bed
  6. Freeboard

The fan feeds the air box under the distributor plate with ambient air. It works against the nozzles and the weight of the bed, typically 700 to 1,100 mmWC on a deep bed. Dilution air for the mixing chamber is a much larger volume at low pressure and is handled by a separate fan or drawn in by the exhaust fan, never by the fluidising fan, which would waste power raising it to bed pressure.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Pressure at the fan outletTypically 700 to 1,100 mmWC
DustClean air; filtered to keep nozzles clear
Duty rangeFrom minimum fluidising flow to full load
Dilution airSeparate low pressure fan or drawn in by the exhaust fan
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for fluidised bed hot air generators

Blade formHigh pressure backward curved or radial bladed wheel
Material of constructionMild steel, with the impeller designed for high tip speed
Drive and arrangementDirect coupled, often at 2,900 rpm
Bearings and coolingStandard bearings; no cooling needed
Flow controlVariable speed drive or inlet guide vanes, with a minimum flow limit
Also specifiedInlet silencer, lagging and non-return damper where two fans share an air box

What this FD fan has to cope with

Bed defluidisation at low load

Cutting air below the minimum fluidising velocity collapses the bed, and the fuel stops mixing and clinkers. The fan control has a floor, and the fan curve must be stable at that floor. Turndown below it is taken by reducing bed temperature or by switching off a bed section on larger units.

Surge with a heavy bed

As the bed builds up with ash and limestone, its resistance rises and a high pressure fan can be pushed towards its stall point, causing pulsation that upsets fluidisation. Selecting the operating point well away from the peak pressure, with the heaviest bed allowed, and draining bed material regularly avoid this.

Nozzle blockage

Dust drawn in with the air, or bed sand falling back through damaged nozzles when the fan stops, blocks the distributor and raises pressure unevenly. Inlet filtration and nozzle designs that resist backflow keep the air distribution even and the fan on its design point.

Energy and control

The fluidising air fan is the largest power consumer on the generator because of its high pressure. Its flow can only be reduced to the fluidisation limit, so the saving from speed control is real but bounded. Keeping bed height at design, draining excess ash and limestone, and keeping dilution air off this fan entirely are the main ways to keep its power down.

ID fan and FD fan in fluidised bed hot air generators

ID fanFD fan
PositionAfter the dryer collectorsUnder the distributor plate
What it handlesHumid exhaust with FBC fly ash and product finesClean ambient air
Temperature at the fan100 to 140°CAmbient
Static pressure250 to 400 mmWC suction700 to 1,100 mmWC
Main design concernFine ash, lime deposits and draft balanceHigh pressure and minimum fluidisation
ControlFreeboard or dryer pressureBed air flow with a minimum limit

See also the Induced Draft (ID) Fan for fluidised bed hot air generators.

Questions buyers ask

What pressure does the fluidising air fan on an FBC hot air generator need?

Typically 700 to 1,100 mmWC, depending on bed depth, bed material and nozzle design. The figure comes from the generator supplier's data or from air box pressure measured with the bed at its normal operating height. The fan is selected with its operating point well clear of the peak of its pressure curve, so a heavier bed does not push it into surge.

Can the FD fan also supply dilution air on a fluidised bed hot air generator?

It should not. Dilution air is a large volume needed at low pressure. Raising it to bed pressure through the fluidising fan wastes a great deal of power. A separate low pressure dilution fan, or air drawn in by the exhaust fan, is the efficient arrangement.

Why does the fluidised bed lose fluidisation when the dryer load drops?

If the fluidising air is reduced along with the fuel, it can fall below the minimum fluidising velocity and the bed slumps, stops mixing and begins to clinker. The fan control must keep a minimum flow, and further turndown is taken through bed temperature and fuel rate, or by running a smaller bed section on larger generators.

Information needed to quote an FD fan for fluidised bed hot air generators

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Bed and distributor. Bed depth, bed material, distributor pressure drop and design air box pressure.
  6. Turndown. Minimum fluidising air flow and the normal operating range.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for fluidised bed hot air generators: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.