Fans and Air Pollution Control for Tea Dryers

Fluid bed and endless chain pressure dryers fire the tea with hot air from a heater and exhaust the moist air with leaf fluff through a dust collector.

The process

Fluid bed and endless chain pressure dryers fire the tea with hot air from a heater and exhaust the moist air with leaf fluff through a dust collector. Hot air fan on the supply, exhaust fan on the outlet.

The gas

Warm, humid air through withering troughs and dryers with light leaf dust. Large volume at low pressure; the fan is cleaned often, so access matters.

Fans in this process

DutyWhat it does hereType usually selected
Hot Air FanCirculates or supplies air at elevated temperature to a dryer, oven or kiln.Backward curved and backward inclined
ID FanSits at the outlet of a boiler, kiln or furnace and draws the flue gas through the plant to the stack.Backward curved, backward inclined and radial tipped
Dust Collector FanThe fan behind a bag filter, cyclone or multiclone on a dust extraction system.Backward inclined and radial tipped

Air pollution control

Industries

Related processes

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.