13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › ID Fan › Titanium Dioxide Calciners

Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Titanium Dioxide Calciners

The ID fan on a titanium dioxide calciner draws the kiln off-gas through the dust recovery, scrubber and wet ESP and controls kiln draft. By the time the gas reaches the fan it is saturated and carries traces of sulphuric acid mist and pigment, so corrosion resistance, not temperature, decides the design.

Send your duty pointCall +91 91766 67102
60 to 80°C, saturated after the scrubberGas temperature, normal
1.02 kg/m³Gas density at 75°C
Backward curved or backward inclinedBlade form

How titanium dioxide calciners work

In the sulphate route to titanium dioxide, washed metatitanic acid pulp from the leaf filters, still holding water and 5 to 8% sulphuric acid, is fed to a long direct-fired rotary kiln. Gas or oil burners at the discharge end heat the product to 850 to 1,000°C, where it dries, loses its acid and converts to anatase or rutile pigment. The gas flows counter-current and leaves the feed end at 300 to 450°C carrying water vapour, SO₂, sulphuric acid vapour and SO₃, and fine pigment. A dust chamber or cyclone returns the coarse fines; the gas is then quenched, scrubbed in a venturi or packed tower and passed through a wet ESP to remove acid mist before the ID fan and stack. The chloride route uses an oxidiser instead of a calciner and is not covered here.

Where the ID fan sits

  1. Rotary calciner
  2. Dust chamber or cyclone
  3. Quench
  4. Venturi or packed scrubber
  5. Wet ESP
  6. ID fan
  7. Stack

Placing the fan after the scrubber and wet ESP keeps it clear of the hot acid vapour and the bulk of the pigment, which is recovered upstream. The gas is saturated at 60 to 80°C. The fan must overcome the kiln, dust chamber, quench, scrubber and ESP, typically 400 to 700 mmWC, and holds the kiln feed end at a slight suction so that acid fume does not escape at the feed chute and seals.

Gas at the ID fan

Gas temperature, normal60 to 80°C, saturated after the scrubber
Maximum or upsetUp to 200 to 300°C if quench water fails; a temperature trip protects the fan
Dust at the fanLow; fine TiO₂ pigment, sticky when wet
Moisture and dew pointSaturated, with free droplets carried from the wet ESP
Corrosive speciesDilute sulphuric acid mist, residual SO₂ and SO₃
Density at the design temperatureAbout 1.02 kg/m³ at 75°C, 85% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for titanium dioxide calciners

Blade formBackward curved or backward inclined, with open passages that drain
Material of constructionRubber-lined or FRP lined mild steel, or high alloy stainless such as 904L for the impeller
Drive and arrangementBelt or direct drive, arrangement 9 or 8, bearings outside the gas stream
Bearings and coolingStandard bearings; a cooling disc only where the upset temperature requires it
Flow controlVariable speed drive on kiln feed end draft
Also specifiedCasing drain, wash nozzles, acid-resistant shaft seal and a quench failure trip

What this ID fan has to cope with

Dilute acid corrosion

Acid mist that passes the wet ESP collects on the impeller and casing and concentrates as water evaporates, attacking ordinary stainless steel at welds and crevices. Lined construction or high alloy stainless, with smooth, fully welded surfaces, gives a long life.

Pigment and gypsum deposits

Fine pigment, and gypsum from any lime used in scrubbing, settle as a wet paste on the blades. As it dries and flakes unevenly the fan vibrates. Wash nozzles at the inlet and a regular wash routine keep the rotor clean.

Quench failure

If quench water fails, hot acid gas reaches lined ducts and the fan, damaging rubber or FRP within minutes. A temperature trip, emergency water and a design that tolerates the short upset protect the fan.

Energy and control

TiO₂ calciners run continuously, with throughput varied by grade. The ID fan works against a high, fairly steady resistance from the scrubbing train. A variable speed drive on kiln draft lets the fan follow grade changes and avoids pulling excess air through the kiln seals, which would cool the product zone and raise burner fuel.

ID fan and FD fan in titanium dioxide calciners

ID fanFD fan
PositionAfter scrubber and wet ESP, before the stackAt the kiln discharge end, feeding the burner
What it handlesSaturated acidic kiln off-gasAmbient air
Temperature at the fan60 to 80°CAmbient
Main design concernDilute sulphuric acid corrosionStable burner air
ControlKiln feed end draftAir main pressure and air split

See also the Forced Draft (FD) Fan for titanium dioxide calciners.

Questions buyers ask

Where is the ID fan placed on a titanium dioxide kiln?

Usually after the quench, scrubber and wet ESP, where the gas is saturated at 60 to 80°C. This keeps the fan out of the hot acid gas and the main pigment dust load, but requires corrosion-resistant construction.

What material is used for a TiO₂ calciner ID fan?

Rubber-lined or FRP lined mild steel, or high alloy stainless steel for the impeller, because the gas carries dilute sulphuric acid mist. Plain mild steel and standard grades corrode quickly in this duty.

Why does a titanium dioxide calciner need draft control?

The kiln must stay at slight suction at the feed end so that acid fume and pigment do not escape at seals and chutes. Too much suction draws in cold air, which cools the kiln and increases fuel use.

Information needed to quote an ID fan for titanium dioxide calciners

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Off-gas cleaning train. Equipment between kiln and fan, with the pressure drop and outlet temperature of each.
  6. Acid content. Expected acid mist and SO₂ at the fan inlet, and quench failure temperature and duration.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for titanium dioxide calciners: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote