13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › ID Fan › Tar and Heavy Residue Fired Boilers

Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Tar and Heavy Residue Fired Boilers

On a tar and heavy residue fired boiler the ID fan pulls flue gas through the boiler, air heater and dust collector and holds the furnace at balanced draft. The gas carries SO₃ and sticky soot, so the decision that governs the fan is keeping every surface above the acid dew point.

Send your duty pointCall +91 91766 67102
170 to 220°C after the air heaterGas temperature, normal
0.75 kg/m³Gas density at 200°C
Backward curved with a self-cleaning blade profileBlade form

How tar and heavy residue fired boilers work

Tar and heavy residue fired boilers burn by-products such as coal tar, pitch, vacuum residue, asphalt and visbreaker tar, usually in chemical plants, coke works and refineries that produce them. The fuel is heated to about 110 to 160°C to bring its viscosity down for steam atomisation. Calorific value is high, typically 8,500 to 9,800 kcal/kg, but so are carbon to hydrogen ratio, sulphur, often 1 to 5%, and metals such as vanadium and nickel. Combustion produces soot and unburnt carbon cenospheres. The gas passes the boiler bank, economiser and air heater, then usually a multiclone, ESP or bag filter to meet particulate limits, before the ID fan and stack. The FD fan supplies combustion air through a steam coil air heater and the main air heater.

Where the ID fan sits

  1. Furnace
  2. Boiler bank
  3. Economiser
  4. Air heater
  5. Multiclone or ESP or bag filter
  6. ID fan
  7. Stack

The fan sits after the dust collector, which removes most of the cenospheres and soot, and before the stack. Gas reaches it at about 170 to 220°C, deliberately kept higher than on a clean oil boiler because the acid dew point with 2 to 5% sulphur fuel can be around 130 to 160°C. The fan suction covers the furnace draft, boiler and economiser, the air heater and the collector, typically 150 to 300 mmWC.

Gas at the ID fan

Gas temperature, normal170 to 220°C after the air heater
Maximum or upsetUp to 280°C with heavy soot fouling or soot blower faults
Dust at the fanFine soot and carbon cenospheres; low after a bag filter or ESP, several hundred mg/Nm³ after a multiclone only
Moisture and dew pointAcid dew point typically 130 to 160°C depending on fuel sulphur and excess air
Corrosive speciesSO₃ and sulphuric acid, vanadium and sodium compounds in the ash
Density at the design temperatureAbout 0.75 kg/m³ at 200°C, 63% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for tar and heavy residue fired boilers

Blade formBackward curved with a self-cleaning blade profile, or radial tipped where soot load is high
Material of constructionMild steel with corrosion allowance; corrosion-resistant steel for the casing bottom and drains where cold spots occur
Drive and arrangementDirect coupled, arrangement 8
Bearings and coolingPedestal bearings with a shaft cooling disc
Flow controlVariable speed drive on furnace draft
Also specifiedExternal insulation and cladding on casing and inlet box, a low-point drain, and an access door for washing

What this ID fan has to cope with

Cold-end acid corrosion

Where the casing is uninsulated, at drains, inspection doors and the inlet box corners, the metal runs below the gas temperature and acid condenses. It mixes with soot to form a corrosive paste. Full insulation, heated or insulated doors and a fan that is kept running during short stops keep the metal above dew point.

Sticky soot build-up on the blades

Residue soot is oily and acidic and sticks to the blade pressure faces, unevenly. Vibration rises as the deposit grows and then drops when pieces break away. A self-cleaning blade shape, access for washing during shutdowns and in-situ balancing manage it. Keeping excess air correct at the burners reduces the soot reaching the fan in the first place.

Fouled air heater raising duty

Heavy fuels foul the air heater quickly, raising resistance and gas temperature together. The fan is selected for the fouled condition and the higher temperature, so it still holds furnace draft before the next soot blowing or water washing. Monitoring the fan current and inlet temperature trend shows when the heater needs cleaning, well before draft is lost and the boiler must shed load.

Energy and control

Residue fired boilers usually run continuously at fairly steady load, since the plant burns the by-product as it is made. Fan energy depends heavily on how fouled the boiler is: a choked air heater can add a large share to the ID fan power. A variable speed drive holding furnace draft saves energy at part load, but regular soot blowing and controlled excess air save more by keeping resistance and gas volume down.

ID fan and FD fan in tar and heavy residue fired boilers

ID fanFD fan
PositionAfter the dust collector, before the stackBefore the steam coil and main air heaters
What it handlesAcidic flue gas with soot and cenospheresClean ambient air
Temperature at the fan170 to 220°C, up to 280°C fouledAmbient, 25 to 45°C
Main design concernAcid dew point and sticky depositsTight excess air at the burners
ControlFurnace draftAir flow and oxygen trim

See also the Forced Draft (FD) Fan for tar and heavy residue fired boilers.

Questions buyers ask

Why does the ID fan on a tar fired boiler corrode?

Tar and residues contain sulphur, and part of it forms SO₃, which condenses as sulphuric acid wherever the metal is below the acid dew point, often 130 to 160°C. Uninsulated casings, drains and doors run cooler than the gas and corrode first. Insulation and higher gas temperatures prevent it.

Can an existing furnace oil boiler ID fan be used for vacuum residue firing?

Sometimes, but check the duty. Residue firing usually needs more soot blowing, higher exit gas temperature and an added dust collector, all of which raise volume and resistance. The fan, its materials and its insulation should be reviewed for the new fuel. Measuring the present gas flow and suction gives the starting point.

Does a heavy residue boiler need a dust collector before the ID fan?

In most cases yes. Residue and tar combustion produces soot and carbon cenospheres, and particulate limits generally require an ESP or bag filter. Placing the ID fan after it protects the fan from deposits and wear. The collector also captures the vanadium-bearing ash that would otherwise build up on the blades and corrode the casing at cold spots.

Information needed to quote an ID fan for tar and heavy residue fired boilers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Fuel analysis. Fuel type, sulphur, vanadium and sodium content, and the atomising temperature.
  6. Dust collection. Type of collector before the fan and the measured dust and gas temperature at the fan inlet.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for tar and heavy residue fired boilers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote