Induced Draft (ID) Fan for Mini Blast Furnaces

On a mini blast furnace the ID fan is usually the exhaust fan of the cast house and stock house dedusting system, drawing fume and dust through a bag filter. The stoves of most mini blast furnaces work on chimney draft. Abrasive dust and fume in hot air decide the ID fan design.

Send your duty pointCall +91 91766 67102
70 to 120°C at the fan, air with fumeGas temperature, normal
0.95 kg/m³Gas density at 100°C
Backward curved with wear linersBlade form

How mini blast furnaces work

Mini blast furnaces, typically 100 to 450 m³ working volume, produce hot metal or foundry pig iron from lump ore or sinter, coke and fluxes. Cold blast at about 1 to 2 bar from a centrifugal blower or compressor is heated to 900 to 1,100°C in three stoves fired with the furnace's own lean BF gas, often without enrichment. The top gas is cleaned in a dust catcher and wet scrubber or dry bag filter and used in the stoves, boilers and reheating furnaces. The blast blower is a compressor duty outside the normal fan range. The fan duties are the stove combustion air fan and the exhaust fans of the cast house and stock house dust extraction systems.

Where the ID fan sits

  1. Tap hole and runner hoods
  2. Stock house pick-up points
  3. Spark arrestor
  4. Bag filter
  5. Exhaust (ID) fan
  6. Stack

The fan sits after the bag filter. It draws fume from hoods at the tap hole, runners and tilting runner during casting, and dust from conveyor transfers and screens in the stock house. The suction at the fan inlet covers hoods, ducts, spark arrestor and filter, typically 250 to 400 mmWC. Cast house fume arrives at 80 to 150°C after dilution with air, so the fan handles hot dusty air, not combustion gas.

Gas at the ID fan

Gas temperature, normal70 to 120°C at the fan, air with fume
Maximum or upsetUp to 180°C during casting with hoods close to the runner
Dust at the fanBelow 50 mg/Nm³ of fine iron oxide and graphite after the filter; coke and ore dust from the stock house
Moisture and dew pointAir; dew point not limiting
Corrosive speciesMinor; some SO₂ from the slag
Density at the design temperatureAbout 0.95 kg/m³ at 100°C, 79% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for mini blast furnaces

Blade formBackward curved with wear liners, or radial where the filter is unreliable
Material of constructionMild steel with wear-resistant plate on blades and scroll
Drive and arrangementDirect coupled, arrangement 8
Bearings and coolingPedestal bearings with a cooling disc
Flow controlVariable speed drive with higher speed during casting
Also specifiedInlet damper, inspection door, and dampers to switch flow between cast house and stock house

What this ID fan has to cope with

Fume escapes during casting

If the fan cannot draw enough at the tap hole, fume escapes to the cast house floor. Capture velocity at the hoods sets the flow, and the fan is selected for casting duty. Separate dampers let the fan concentrate flow on the cast house during casting.

Abrasive dust at the fan

Coke, ore and sinter dust from the stock house is highly abrasive, and broken bags quickly erode the impeller. Wear liners and broken bag detection limit damage. Stock house dust is the hardest, and that branch may need wear-lined duct bends of its own.

Sparks and filter fires

Hot metal sparks, burning graphite and hot slag particles can be drawn into the ducts and reach the bag filter, starting a fire that destroys bags and lets dust through to the fan. A spark arrestor or cooling chamber ahead of the filter protects the bags, and with them the fan, from the dust surge that follows bag failure.

Energy and control

Casting takes place several times a shift, and between casts the cast house hoods need much less flow. A variable speed drive that raises speed during casting and drops it between casts saves considerable energy. Switching dampers between cast house and stock house duty also allows one fan to serve both.

ID fan and FD fan in mini blast furnaces

ID fanFD fan
PositionAfter the dedusting bag filterAhead of the stove air main
What it handlesHot air with fume and dustAmbient combustion air
Temperature at the fan70 to 120°CAmbient, 25 to 45°C
Main design concernCapture flow and abrasionAir-gas ratio on lean gas
ControlCasting scheduleAir-gas ratio

See also the Forced Draft (FD) Fan for mini blast furnaces.

Questions buyers ask

What fans does a mini blast furnace need?

A blast blower or compressor for cold blast, a combustion air fan for the stoves, and exhaust fans for cast house and stock house dedusting. Some plants also have ID fans for gas-fired boilers using BF gas. The duties are quite different. Each needs its own selection.

Is the blast blower of a mini blast furnace an FD fan?

No. Cold blast at 1 to 2 bar needs a centrifugal blower or compressor. The FD fan in a mini blast furnace is the stove combustion air fan. It is a separate machine with its own cooling and surge protection. It is specified separately from the fans.

What is the cast house dedusting fan duty in a mini blast furnace?

It draws fume from tap hole and runner hoods through a bag filter. The flow is set by capture velocity at the hoods, and the fan handles hot air with fine iron oxide and graphite. Stock house dust may be handled by the same fan through switching dampers.

Information needed to quote an ID fan for mini blast furnaces

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Capture points. Number and type of hoods at the cast house and stock house, and casting schedule.
  6. Filter. Bag filter type and outlet dust level.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for mini blast furnaces: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.