Induced Draft (ID) Fan for Match Splint Dryers

The ID fan on a match splint dryer is the drum exhaust fan. It draws humid air from the rotary dryer through the cyclone and keeps the drum under slight suction so wood dust does not leak. Its air carries hygroscopic phosphate dust and combustible wood fines, so build-up, corrosion and fire risk decide its design.

Send your duty pointCall +91 91766 67102
45 to 70°C, humid exhaust airGas temperature, normal
1.06 kg/m³Gas density at 60°C
Radial tipped or open backward curvedBlade form

How match splint dryers work

Match splints are cut from peeled veneer of soft woods such as poplar, aspen or local softwoods, then soaked in an ammonium phosphate solution so the stick does not glow after the flame goes out. The wet splints, at 50% moisture or more, are dried to about 6 to 10% in rotary drum dryers. Hot air at typically 80 to 130°C comes from a wood-waste or husk-fired furnace through an indirect heat exchanger, or from steam coils. The drum tumbles the splints in the air, and the exhaust leaves at 45 to 70°C, humid and carrying wood fines and phosphate dust, through a cyclone to atmosphere. Dried splints are polished in drums before the match machine. Many small units still sun dry.

Where the ID fan sits

  1. Rotary drum dryer
  2. Exhaust hood
  3. Cyclone
  4. ID fan
  5. Exhaust stack

The fan sits after the cyclone, which removes broken splints and coarse fines, so it handles fine wood dust and phosphate. It works against the drum, exhaust hood, cyclone and ducting, typically 80 to 180 mmWC. Small dryers often have only a supply blower, but an exhaust fan is needed to keep dust out of the work area and to control drum pressure when several dryers share a heater.

Gas at the ID fan

Gas temperature, normal45 to 70°C, humid exhaust air
Maximum or upsetUp to 100 to 120°C when the drum runs empty
Dust at the fanWood fines and ammonium phosphate dust after the cyclone
Moisture and dew pointHumid early in each batch; condensation in cold ducts
Corrosive speciesAmmonium phosphate, hygroscopic and mildly corrosive when damp
Density at the design temperatureAbout 1.06 kg/m³ at 60°C, 88% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for match splint dryers

Blade formRadial tipped or open backward curved, which shed fibrous dust
Material of constructionMild steel with an epoxy coating, or stainless steel where damp phosphate deposits are persistent
Drive and arrangementBelt driven, arrangement 9
Bearings and coolingStandard pedestal bearings
Flow controlInlet damper, or variable speed drive where several drums share a fan
Also specifiedInspection door, casing drain, earthing against static, and spark detection on larger systems

What this ID fan has to cope with

Phosphate and wood dust build-up

Ammonium phosphate is hygroscopic. In humid exhaust it absorbs water and cements wood fines onto the impeller and scroll. Deposits harden, unbalance the wheel and cut flow. Self-cleaning blades, an inspection door and washing at regular stops prevent this. Good cyclone performance and dry splints at discharge reduce the load.

Corrosion of mild steel

Damp phosphate deposits slowly corrode uncoated mild steel, especially at the casing bottom. A coating, stainless parts where wetting persists and a casing drain extend life. Fasteners and the inspection door frame, where deposits collect and water sits, are worth making in stainless steel from the start, since they are hard to replace once corroded.

Fire in the dryer exhaust

Dry wood fines are combustible, and sparks from a wood-fired heater can enter through a leaking heat exchanger. Indirect heating, a spark screen on the hot air duct, a tight exchanger and earthing of the fan reduce the risk. Keep the cyclone hopper emptied and closed.

Energy and control

Splint dryers work in batches, with moisture removal high at the start and low at the end. An exhaust fan sized for the wettest moment runs oversized for most of the batch. Reducing exhaust flow late in the batch, by damper or speed, saves fan power and wood fuel. Small plants that run seasonally gain most from a correctly sized fan rather than a large one throttled.

ID fan and FD fan in match splint dryers

ID fanFD fan
PositionAfter the cyclone, before the exhaust stackBefore the heat exchanger, feeding the drum
What it handlesHumid air with wood and phosphate dustClean ambient air
Temperature at the fan45 to 70°CAmbient
Main design concernBuild-up, corrosion and fireSpark-free air and even flow
ControlDrum suctionDrying air flow

See also the Forced Draft (FD) Fan for match splint dryers.

Questions buyers ask

What fan is used for a match splint dryer exhaust?

A radial tipped or open backward curved centrifugal fan after a cyclone is usual. It handles warm humid air with wood fines and ammonium phosphate dust, so it must shed deposits and resist mild corrosion. Belt drive allows speed to be matched to the drum, and an inspection door allows regular cleaning.

Why does dust stick to my splint dryer fan?

The ammonium phosphate used to treat the splints absorbs moisture and binds wood fines together on the blades. Washing the fan at regular stops and using a self-cleaning blade form reduces build-up. Improving the cyclone and keeping the duct warm so that the phosphate does not pick up moisture also helps.

Does a match splint dryer need an ID fan?

Small dryers can run with only a supply blower, but an induced draft fan keeps the drum under suction, contains dust and gives better control of drying, especially in larger units. Where several drums share one heater, an exhaust fan also helps balance the air between them.

Information needed to quote an ID fan for match splint dryers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Dryer data. Drum size, splints dried per batch and moisture removed.
  6. Heat source. Heater type and whether the air is heated directly or through an exchanger.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for match splint dryers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote