Induced Draft (ID) Fan for Detergent Spray Drying Towers

The ID fan on a detergent spray drying tower draws the moist, dust-laden exhaust from the top of the tower through the cyclones and scrubber or filter. Sticky alkaline fines and the surfactant haze decide its design, together with the fire risk from deposits in the tower and ducts.

Send your duty pointCall +91 91766 67102
85 to 110°C after the cyclones; 55 to 65°C if the fan follows the scrubberGas temperature, normal
0.95 kg/m³Gas density at 100°C
Backward curved plate or radial-tippedBlade form

How detergent spray drying towers work

Detergent powder is made by mixing surfactant (usually neutralised LABSA), sodium sulphate, soda ash, silicate and other builders into a slurry of about 60 to 70% solids, then pumping it at high pressure to nozzles near the top of a tall counter-current tower. Hot gas from an oil or gas-fired furnace, typically 250 to 350°C, enters through a ring main near the bottom and rises against the falling droplets, which dry into hollow beads. The powder leaves the cone at about 70 to 90°C and goes to an airlift that cools it. The exhaust leaves the top at about 85 to 110°C, laden with fine detergent dust and a blue haze of surfactant mist, and passes cyclones and a wet scrubber or bag filter before the stack. The tower runs at a slight suction.

Where the ID fan sits

  1. Counter-current tower
  2. Tower top outlet
  3. Cyclones
  4. Exhaust (ID) fan
  5. Wet scrubber
  6. Stack

On many towers the exhaust fan follows the cyclones and pushes into a wet scrubber, so it handles hot gas with the fines the cyclones miss. Where a bag filter is used, the fan follows the filter and sees much less dust; where the scrubber comes first, the fan handles saturated gas with alkaline droplets. The suction holds the tower top slightly below atmospheric, and covers the cyclones and, where upstream, the scrubber; typically 200 to 400 mmWC.

Gas at the ID fan

Gas temperature, normal85 to 110°C after the cyclones; 55 to 65°C if the fan follows the scrubber
Maximum or upsetUp to 150°C if the slurry feed is lost
Dust at the fanFine, sticky detergent fines, often 0.5 to 2 g/m³ after cyclones
Moisture and dew pointHigh moisture from slurry water; dew point around 55 to 65°C
Corrosive speciesAlkaline dust and droplets (carbonate, silicate); combustion products from the furnace
Density at the design temperatureAbout 0.95 kg/m³ at 100°C, 79% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for detergent spray drying towers

Blade formBackward curved plate or radial-tipped, open shape that sheds sticky fines
Material of constructionMild steel after cyclones; SS 304 or coated steel where the fan handles scrubber gas
Drive and arrangementBelt or direct driven, with a variable speed drive
Bearings and coolingPedestal bearings with cooling disc; shaft seal against dust and moisture
Flow controlVariable speed drive on tower top pressure
Also specifiedWash nozzles, large inspection doors, casing drain and earthing

What this ID fan has to cope with

Sticky build-up on the blades

Detergent fines are hygroscopic and the surfactant part softens when warm and moist, so they coat the blades and casing. Uneven deposits throw the rotor out of balance. An open blade shape, wash nozzles and a regular wash routine at tower stops keep it under control.

Tower and duct fires

Organic surfactant deposits on tower walls and in the exhaust duct can ignite if the tower overheats. The ID fan is interlocked with the furnace and slurry pumps, and the tower fire procedure defines whether the fan stops or runs to clear smoke.

Wet alkaline gas after the scrubber

Where the fan follows the scrubber, it sees saturated gas with alkaline droplets that dry into crusts on the impeller. Stainless or coated parts, a mist eliminator before the fan and a casing drain prevent crusting and corrosion.

Energy and control

Detergent towers run in campaigns between formulation changes and wall-cleaning stops. Tower output and outlet temperature follow the slurry rate, so a variable speed drive on the exhaust fan saves power against damper control. Raising slurry solids and reducing air leakage at the tower door and cone cut the gas volume per tonne of powder.

ID fan and FD fan in detergent spray drying towers

ID fanFD fan
PositionAfter cyclones, before or after the scrubberAt the hot gas furnace
What it handlesMoist exhaust with sticky detergent finesAmbient combustion and dilution air
Temperature at the fan85 to 110°CAmbient
Main design concernSticky deposits and fire riskUniform inlet gas temperature
ControlTower top pressureFiring rate and inlet temperature

See also the Forced Draft (FD) Fan for detergent spray drying towers.

Questions buyers ask

Where is the ID fan on a detergent spray drying tower?

Usually after the cyclones and before the wet scrubber, so the fan handles hot gas with residual fines. Some plants place it after the scrubber or after a bag filter, which changes what it sees: wet alkaline gas or very little dust.

Why do detergent tower exhaust fans go out of balance?

Hygroscopic detergent fines and surfactant mist stick to the blades in the warm, humid exhaust. The deposits grow and break off unevenly. Regular washing and a blade shape that sheds deposits reduce how often the fan needs balancing.

What causes the blue haze from a detergent tower?

Fine droplets of surfactant and organic matter that evaporate in the hot zone and recondense as a sub-micron mist. Cyclones do not catch them, so a wet scrubber or other control is needed, and the ID fan pressure must cover it.

Information needed to quote an ID fan for detergent spray drying towers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Gas cleaning order. Whether the fan follows cyclones, a bag filter or the wet scrubber, with each pressure drop.
  6. Formulation. Surfactant level and builders, which affect stickiness and the exhaust moisture.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for detergent spray drying towers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote