Induced Draft (ID) Fan for Container Glass Furnaces

The ID fan on a container glass furnace pulls waste gas from the regenerators through the scrubber and ESP and holds the crown pressure. Cullet with labels, organics and coatings, and heavy sulphate fining, make the gas sticky and acidic, so deposit control and corrosion protection decide the design.

Send your duty pointCall +91 91766 67102
300 to 380°C after a hot ESP; 180 to 230°C after a waste heat boilerGas temperature, normal
0.58 kg/m³Gas density at 340°C
Backward inclinedBlade form

How container glass furnaces work

Container glass furnaces melt soda-lime glass for bottles and jars, usually in end-port regenerative furnaces of 150 to 400 tonnes per day, with recuperative and oxy-fuel furnaces on some lines. Batch is sand, soda ash, limestone, dolomite and a high share of cullet, often 40 to 80%, with sodium sulphate as fining agent. Melting runs at about 1,500 to 1,550°C, firing alternating between the two ports every 20 to 30 minutes. Waste gas leaves the regenerators at 450 to 550°C carrying sodium sulphate, SO₂ and traces of HCl and HF. Modern lines add dry or semi-dry scrubbing with hydrated lime and an ESP, sometimes a waste heat boiler, with the ID fan after the ESP.

Where the ID fan sits

  1. Melter
  2. End-port regenerator
  3. Reversing valve
  4. Dry scrubber
  5. ESP
  6. ID fan
  7. Chimney

The fan stands after the ESP, with a bypass damper to the original chimney so the furnace can run on natural draft during filter maintenance or a fan trip. Gas reaches the fan at 300 to 380°C with a hot ESP, or 180 to 230°C if a waste heat boiler cools it first. Total suction is typically 150 to 300 mmWC. Crown pressure is held slightly positive, and reversal every 20 to 30 minutes causes a short pressure swing that the fan control must absorb.

Gas at the ID fan

Gas temperature, normal300 to 380°C after a hot ESP; 180 to 230°C after a waste heat boiler
Maximum or upsetUp to 500°C when gas cooling or the boiler is bypassed
Dust at the fanFine sodium sulphate and lime, below about 30 mg/Nm³ after the ESP
Moisture and dew pointAbout 10 to 15% water; dew point 50 to 55°C
Corrosive speciesSO₂, SO₃, HCl and HF; acid dew point roughly 140 to 170°C
Density at the design temperatureAbout 0.58 kg/m³ at 340°C, 48% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for container glass furnaces

Blade formBackward inclined, robust and tolerant of light deposits
Material of constructionBoiler quality plate up to about 380°C; heat-resisting steel impeller where the bypass upset exceeds that
Drive and arrangementDirect coupled, arrangement 8, sliding supports
Bearings and coolingCooling disc, heat shield and oil or water cooled bearings
Flow controlVariable speed drive on crown pressure, coordinated with the chimney bypass
Also specifiedStandby fan or bypass path, cleaning doors, full insulation and slow turning gear

What this ID fan has to cope with

Deposits from cullet contamination

External cullet brings labels, food residues, plastics and metal. These add organics, chlorides and lead or other metals to the waste gas, producing finer and stickier dust than clean batch alone. When the ESP is upset, deposits build on the impeller quickly. Cleaning doors, a blade shape that sheds dust and monitoring vibration trend catch the build-up early.

Reversal pressure swings

End-port furnaces reverse every 20 to 30 minutes. The firing pauses and the gas path changes, and crown pressure jumps. If the ID fan control is slow or over-tuned, it hunts after each reversal. Feed-forward from the reversal signal and a fan with smooth response at the operating point keep the crown steady.

Acid attack during ESP outages

When the ESP is off and the furnace switches to chimney draft, the idle fan and ducts cool, and SO₃ condenses as sulphuric acid on the casing and impeller. Isolation dampers that seal well, a warm air purge or slow rotation, and full insulation protect the idle fan, and it should be dried out before restart.

Energy and control

Container glass furnaces change pull rate with job changes on the forming machines and with colour changes. An ID fan on a variable speed drive follows these changes and the gradual fouling of regenerators. Correct crown pressure also stops air infiltration through the port necks and doghouse, which saves fuel and helps foam and colour control.

ID fan and FD fan in container glass furnaces

ID fanFD fan
PositionAfter the ESP, with a chimney bypassBefore the reversing valve and regenerator
What it handlesWaste gas with sulphate dust and acidsAmbient filtered air
Temperature at the fan180 to 380°CAmbient
Main design concernDeposits and acid dew pointAccurate, steady air flow
ControlCrown pressureAir flow ratioed to fuel

See also the Forced Draft (FD) Fan for container glass furnaces.

Questions buyers ask

Why does a container glass furnace need an ID fan if it has a chimney?

The chimney was sized for the regenerators alone. Adding a dry scrubber and ESP adds 100 mmWC or more of resistance that the chimney cannot provide on its own. The ID fan supplies this extra draft, while the chimney stays as the bypass path for filter maintenance and for emergencies if the fan trips.

What temperature should the ID fan on a container glass furnace operate at?

Typically 300 to 380°C after a hot ESP, or 180 to 230°C after a waste heat boiler. The gas should always stay above the acid dew point, roughly 140 to 170°C on a sulphate-fined furnace, so ducts and the fan casing must be fully insulated.

How does high cullet use affect the ID fan?

More cullet saves energy and lowers the gas volume per tonne of glass, but external cullet brings contaminants. The waste gas then carries more chlorides, organics and fine dust, which are sticky and corrosive. The fan needs cleaning access, robust blades and protection against acid condensation, and the ESP needs to stay efficient.

Information needed to quote an ID fan for container glass furnaces

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Furnace and pull. End-port, cross-fired or oxy-fuel, pull in tonnes per day and cullet ratio.
  6. Bypass arrangement. How the chimney bypass works and the gas temperature in bypass mode.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.