Induced Draft (ID) Fan for Black Liquor Chemical Recovery Boilers

The ID fan on a black liquor recovery boiler draws gas through the boiler, economiser and ESP and holds the furnace at a stable negative pressure. Sticky salt cake fume and the safety role of draft in a smelt-water emergency decide its design.

Send your duty pointCall +91 91766 67102
160 to 200°C after the economiser and ESPGas temperature, normal
0.78 kg/m³Gas density at 180°C
Backward curved with smooth blades that shed salt cakeBlade form

How black liquor chemical recovery boilers work

A kraft or soda recovery boiler burns black liquor, the spent cooking liquor from pulping, concentrated in evaporators to typically 65 to 80% solids. The liquor is sprayed into the lower furnace, where it dries and forms a char bed on the hearth. The organic part burns, and the inorganic sodium and sulphur compounds leave as molten smelt through spouts to the dissolving tank. The flue gas carries sodium sulphate and carbonate fume, with chlorides and potassium, which deposits on the superheater and boiler bank and is removed by sootblowers. An ESP recovers this salt cake for return to the liquor. Air enters at primary, secondary and tertiary levels from separate FD fans, and an ID fan draws the gas through the ESP to the stack.

Where the ID fan sits

  1. Furnace and char bed
  2. Superheater
  3. Boiler bank
  4. Economiser
  5. ESP
  6. ID fan
  7. Stack

The fan sits after the ESP, which removes most of the salt cake fume. The fan still sees fine sodium salts, which are hygroscopic and stick to cool surfaces. Suction covers furnace draft, the heavily fouled superheater and boiler bank, the economiser and the ESP, typically 200 to 350 mmWC, rising as deposits build between sootblowing cycles and water washes. Large boilers use two ID fans in parallel so one can be maintained without a full shutdown.

Gas at the ID fan

Gas temperature, normal160 to 200°C after the economiser and ESP
Maximum or upsetUp to 250°C with heavy fouling before a water wash
Dust at the fanFine sodium sulphate and carbonate fume; low after a working ESP, high if a field trips
Moisture and dew pointHigh moisture from liquor water; salt cake absorbs moisture at shutdown
Corrosive speciesChlorides, SO₂ and TRS compounds; corrosive in wet salt deposits
Density at the design temperatureAbout 0.78 kg/m³ at 180°C, 65% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for black liquor chemical recovery boilers

Blade formBackward curved with smooth blades that shed salt cake
Material of constructionMild steel casing, insulated; corrosion-resistant steel for the impeller where deposits stay wet at shutdown
Drive and arrangementDirect coupled, arrangement 8; two fans in parallel on large boilers
Bearings and coolingPedestal bearings with cooling disc
Flow controlVariable speed drive on furnace draft, inlet damper for isolation
Also specifiedWash nozzles, inspection door, casing drain and insulation

What this ID fan has to cope with

Salt cake deposits and unbalance

Sodium salts that pass the ESP stick to the blades, especially where the gas is near its moisture saturation at low load. Deposits grow unevenly and break away, causing vibration. Smooth blade forms, wash nozzles and insulation keep the build-up under control between shutdowns.

Corrosion of deposits at shutdown

When the boiler stops, the salt cake on the fan absorbs moisture from the air and forms a corrosive, chloride-bearing paste. Washing and drying the fan after shutdown and keeping the casing closed prevent pitting of the impeller and casing.

Draft during an emergency drain

If a tube leak lets water into the smelt bed, the boiler goes through an emergency shutdown and rapid drain. The ID fan must keep the furnace under suction to vent steam and combustion gases safely, so its power supply and controls are part of the boiler safety system.

Rising resistance between washes

Fouling of the superheater and boiler bank raises suction steadily between water washes, and the gas temperature at the fan rises with it. The fan is selected with margin for the fouled condition at full liquor firing, so the boiler does not have to cut load as the run progresses and the mill does not lose pulp production.

Energy and control

Recovery boilers run at a load set by liquor solids flow, which is steady but rises as the mill increases production. A variable speed drive on furnace draft gives savings at reduced firing and during start-up on auxiliary fuel. Efficient sootblowing and regular water washing keep the boiler resistance and gas temperature down, which reduces ID fan power more than any change to the fan.

ID fan and FD fan in black liquor chemical recovery boilers

ID fanFD fan
PositionAfter the ESP, before the stackBefore the steam coil air heaters, one fan per air level
What it handlesFlue gas with sodium salt fumeAmbient or boiler house air
Temperature at the fan160 to 200°CAmbient
Main design concernSalt cake deposits and draft reliabilityAir split and port pressure
ControlFurnace draftAir flow at each level

See also the Forced Draft (FD) Fan for black liquor chemical recovery boilers.

Questions buyers ask

What dust does a recovery boiler ID fan handle?

Fine sodium sulphate and sodium carbonate fume, with some chlorides and potassium. A working ESP removes most of it, but what reaches the fan is sticky and hygroscopic, so deposits and corrosion are the main concerns rather than erosion. If an ESP field trips, the load rises sharply and the fan needs washing sooner.

Why do recovery boilers use two ID fans?

Two fans in parallel let the boiler keep running at reduced load if one fan is out for washing or repair, and they give redundancy for the furnace draft, which is a safety function on a recovery boiler. The fans are checked for stable parallel running at low load so that neither stalls during start-up on auxiliary fuel.

How is the ID fan cleaned on a black liquor recovery boiler?

Usually with wash nozzles in the inlet box and casing, used during planned shutdowns with the fan isolated and turning slowly. Washing removes the salt cake before it absorbs moisture and becomes corrosive. The casing is drained and the fan is dried with warm air before restart, then checked for vibration.

Information needed to quote an ID fan for black liquor chemical recovery boilers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Liquor and firing. Dry solids firing rate, liquor solids content, and whether the liquor is wood or agro-based.
  6. ESP and fouling. ESP outlet dust and the draft profile between water washes.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for black liquor chemical recovery boilers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.