Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Biscuit Ovens

On a biscuit oven the ID fans are the zone extraction fans that draw steam, fat vapour and the combustion products of the ribbon burners out of the baking chamber. Their flow sets the humidity in each zone and so the biscuit's spread, texture and colour. Fat condensing in the duct and fan, not heat, is the main design issue.

Send your duty pointCall +91 91766 67102
150 to 250°C at the zone extractionGas temperature, normal
0.75 kg/m³Gas density at 200°C
Radial or backward curvedBlade form

How biscuit ovens work

Biscuit, cracker and cookie dough pieces travel through a long continuous oven, often 40 to 100 m, on a steel band or wire mesh. The front zones are usually direct gas fired: rows of ribbon burners above and below the band, fed with a premixed air-gas mixture, release their combustion products straight into the baking chamber. Later zones are often convection, with hot air blown onto the product to dry and colour it. Dough at roughly 15 to 30% moisture leaves at about 1 to 4%, so the oven releases large quantities of steam, together with fat vapour and fine crumbs. Zone extraction fans draw this steam and the burner products out through roof ducts to stacks.

Where the ID fan sits

  1. Ribbon burners and baking chamber
  2. Zone extraction hood
  3. Extraction duct and damper
  4. Grease drain
  5. ID fan
  6. Roof stack

Each zone or pair of zones has a roof extraction duct, with a damper the baker uses to set zone humidity, and an extraction fan before the stack. The fan draws directly from the baking chamber at 150 to 250°C with no collector upstream, so it sees everything the oven gives off: steam, fat aerosol, crumbs and burner gases. Suction is low, typically 10 to 40 mmWC, and the chamber is held close to neutral so heat does not spill from the band entry and exit.

Gas at the ID fan

Gas temperature, normal150 to 250°C at the zone extraction
Maximum or upsetUp to 300°C at the first zones during high-fire start-up
Dust at the fanFine crumbs and flour, with fat aerosol that sticks to cooler surfaces
Moisture and dew pointHigh steam content in the first zones; dew point can reach 60 to 80°C, so a cold casing condenses water and fat
Corrosive speciesNone significant; fat and sugar deposits are the concern
Density at the design temperatureAbout 0.75 kg/m³ at 200°C, 62% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for biscuit ovens

Blade formRadial or backward curved, with smooth blades that shed fat deposits
Material of constructionMild steel, or SS 304 for the wet extraction from the first zones
Drive and arrangementBelt driven or direct coupled, mounted on the oven roof
Bearings and coolingShaft cooling disc, with bearings clear of the hot casing
Flow controlZone damper set by the baker, or variable speed drive on zone humidity
Also specifiedInsulated casing, grease drain at the lowest point, and a cleaning door

What this ID fan has to cope with

Fat deposits and duct fires

Fat aerosol condenses on duct walls and fan blades, building a layer that can be ignited by a burner flame or a spark. Insulated ducts kept above the condensation point, grease drains at low points and at the fan casing, cleaning doors and a fixed degreasing schedule prevent duct and fan fires.

Condensate dripping back onto the band

When the extraction duct or fan casing is cold, steam condenses and runs back into the oven, marking the product. Insulation on duct and casing, a drain at the fan, and ducts that fall away from the oven towards a drain keep condensate out of the baking chamber.

Zone humidity drifting between cleans

Biscuit spread and texture depend on humidity in the early zones. As deposits build in the fan and duct, extraction falls, humidity rises and product dimensions change. Measuring zone humidity or pressure, and a fan on speed control that holds flow as deposits build, keep the product consistent between cleans.

Energy and control

Extraction carries heat away, and every extra cubic metre removed is gas the burners must reheat. Bakers often open extraction dampers wide and leave them there. Replacing fixed dampers with speed control set from zone humidity reduces both fan power and gas use. On larger ovens, heat recovered from the extraction air is used to preheat burner air or process water.

ID fan and FD fan in biscuit ovens

ID fanFD fan
PositionOven roof, on each zone extractionBeside the oven, feeding the burner manifold
What it handlesSteam, fat vapour and burner gasesClean hall or outside air
Temperature at the fan150 to 250°C30 to 50°C
Main design concernFat deposits and zone humiditySteady manifold pressure
ControlZone humidityManifold pressure

See also the Forced Draft (FD) Fan for biscuit ovens.

Questions buyers ask

Why is the extraction fan on a biscuit oven important for product quality?

The extraction fans set the humidity in each zone of the biscuit oven. In the first zones humidity controls how the dough spreads and sets; later it affects drying and colour. Too little extraction gives soft, pale biscuits, while too much dries the surface early, limits spread and raises gas use.

How do you prevent fat fires in biscuit oven exhaust ducts?

Keep the ducts and fan warm with insulation so fat vapour does not condense, fit grease drains at low points and at the fan casing, provide cleaning doors, and clean on a fixed schedule. The fan should have smooth blades without ledges where fat collects, and extraction should be proven before the burners light.

What temperature does a biscuit oven exhaust fan handle?

Typically 150 to 250°C at the zone extraction, with the first zones hottest during start-up. The fan is designed for the upset temperature, with a shaft cooling disc and bearings clear of the casing, and its rating is corrected for hot, humid air, which is lighter than ambient air.

Information needed to quote an ID fan for biscuit ovens

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Zones. Number of extraction points, the zones each fan serves, and whether those zones are direct gas fired or convection.
  6. Humidity control. Whether extraction is set by hand dampers or controlled from zone humidity or pressure.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for biscuit ovens: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.