Forced Draft (FD) Fan for Zeolite and Silica Calciners

The FD fan on a zeolite or silica calciner is the combustion air fan for the discharge end burner. It supplies primary air for flame shape and secondary air for complete combustion, and on many kilns extra air to temper the gas. It handles clean ambient air, but flow must be stable because the product is sensitive to overheating.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How zeolite and silica calciners work

Synthetic zeolites, molecular sieves and silica-based adsorbents are formed as beads, extrudates or spray-dried powder, usually with a clay binder, then calcined at typically 500 to 700°C to set the binder and drive water out of the crystal pores. Some grades are ion exchanged with ammonium salts first, so the calciner also releases ammonia. Direct gas or oil fired rotary kilns are common, with the hot gas flowing counter-current to the product, and some plants use indirect kilns or belt calciners. Zeolites hold 20 to 25% water, so the off-gas is very humid. It leaves the feed end at 200 to 350°C carrying fine, abrasive aluminosilicate dust, passes a cyclone and bag filter, and the ID fan delivers it to the stack.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Primary and secondary air ducts
  4. Burner
  5. Rotary calciner

The fan sits at the discharge end of the kiln, close to the burner. It delivers air through separate primary and secondary ducts, and sometimes to a tempering air port that keeps the gas below the temperature at which the zeolite structure collapses. Outlet pressure is typically 300 to 700 mmWC for gas or oil burners. A separate cooler fan, where fitted, is not part of this duty.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
DustFiltered air; ambient dust in a powder plant can be heavy
Pressure at the fan outletTypically 300 to 700 mmWC
TurndownFiring follows feed rate and grade, about 3:1
Tempering airSome kilns add ambient air to limit gas temperature at the hot end
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for zeolite and silica calciners

Blade formBackward curved, for efficiency on clean air
Material of constructionMild steel
Drive and arrangementDirect coupled, arrangement 4 or 8
Bearings and coolingStandard bearings; no cooling needed
Flow controlVariable speed drive on air main pressure, with control dampers per duct
Also specifiedInlet filter and silencer

What this FD fan has to cope with

Overheating the product

Zeolite crystal structure is damaged above its limit, often 750 to 850°C depending on type. Unstable air and flame can create hot spots. Stable fan pressure and separate tempering air control hold the hot zone within range.

Fine dust at the inlet

Powder handling around the kiln fills the air with fines, which coat the impeller and burner. An inlet filter or a duct from a clean area prevents this.

Poor control at low firing

A fan sized well above duty runs throttled, with unstable air at low firing. Speed control on a correctly sized fan gives smooth turndown. It also reduces wear on the dampers.

Energy and control

The combustion air fan runs whenever the kiln fires. Air demand follows feed and grade. Speed control on air main pressure, with oxygen trim, avoids excess air that adds to the humid off-gas volume, to the bag filter load and to the ID fan power. The fan itself is small, but it runs every hour the kiln fires.

ID fan and FD fan in zeolite and silica calciners

ID fanFD fan
PositionAfter the bag filter, before the stackAt the kiln discharge end, feeding the burner
What it handlesHumid kiln gas with fine abrasive dustAmbient air
Temperature at the fan150 to 220°CAmbient
Main design concernDew point and erosionStable air to avoid overheating
ControlKiln feed end draftFiring rate

See also the Induced Draft (ID) Fan for zeolite and silica calciners.

Questions buyers ask

What does the FD fan supply on a zeolite calciner?

It supplies combustion air to the burner at the discharge end, split into primary and secondary air, and sometimes tempering air to limit the hot zone temperature. The air is ambient and the fan never sees the humid kiln gas.

Why does a zeolite kiln need tempering air?

Zeolite crystals lose their structure if overheated. Tempering air mixed into the hot gas keeps the hot zone below that limit while the burner fires at the rate the throughput needs.

What pressure does a calciner combustion air fan need?

Typically 300 to 700 mmWC for gas or oil burners, enough to give the burner the air velocity it needs for flame shape, plus duct and damper losses.

Information needed to quote an FD fan for zeolite and silica calciners

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner. Burner type, fuel and air pressure needed at full firing.
  6. Tempering. Whether the fan also supplies tempering air and the flow required.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for zeolite and silica calciners: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote