13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Pharmaceutical Spray Dryers

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Pharmaceutical Spray Dryers

The FD fan on a pharmaceutical spray dryer is the process air supply fan in open-cycle units, pushing HEPA-filtered air through the heater to the chamber. Closed-cycle nitrogen units usually have no separate FD fan: the single recirculation blower moves the gas round the whole loop. Where an FD fan exists, air purity and steady flow decide its design.

Send your duty pointCall +91 91766 67102
Ambient or conditioned room air, 15 to 35°CAir temperature at the fan
1.15 kg/m³Air density at 35°C
Backward curved for clean airBlade form

How pharmaceutical spray dryers work

Pharmaceutical spray dryers produce APIs, amorphous solid dispersions, excipients and inhalable particles, usually in small to medium chambers with two-fluid or pressure nozzles. Aqueous feeds dry in open-cycle units: HEPA-filtered air is heated by steam or electric heaters to about 120 to 200°C and leaves at 50 to 90°C through a cyclone and a cartridge or bag filter with a HEPA police filter. Feeds in organic solvents such as acetone, methanol or dichloromethane dry in closed-cycle units with nitrogen: the gas leaves the chamber, passes the cyclone and filter, is cooled in a condenser that recovers the solvent, and is reheated and recirculated by a single blower. Containment of potent compounds, product purity and, for solvents, oxygen levels and explosion risk set the design.

Where the FD fan sits

  1. Air intake
  2. Pre-filter and fine filter
  3. FD (supply) fan
  4. Heater
  5. HEPA filter
  6. Air disperser
  7. Drying chamber

The supply fan follows the pre-filters and sits before the heater and terminal HEPA filter, so it handles cool, filtered air. Because the HEPA filter is downstream, anything from the fan itself is caught before the chamber. The fan pressure covers the filters at their dirty pressure drop, the heater, the HEPA filter and the disperser. In closed cycle, this role is taken by the recirculation blower.

Air at the FD fan

Air temperature at the fanAmbient or conditioned room air, 15 to 35°C
Air after the heater120 to 200°C, downstream of the fan
DustPre-filtered air; terminal HEPA filtration after the heater
HumiditySome plants dehumidify inlet air for consistent product moisture
PressureFilters, heater, HEPA filter and disperser
Density at the design temperatureAbout 1.15 kg/m³ at 35°C, 96% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for pharmaceutical spray dryers

Blade formBackward curved for clean air
Material of constructionSS 304 or SS 316L
Drive and arrangementDirect driven with a variable speed drive
Bearings and coolingSealed bearings outside the air path
Flow controlVariable speed drive on measured air flow
Also specifiedCleanable casing, documented materials, low-shedding gaskets

What this FD fan has to cope with

Batch-to-batch repeatability

Particle size and moisture depend on the gas flow, so the supply fan must deliver the same flow every batch as filters load. Flow measurement and speed control hold it, and the setpoint is part of the batch record.

Wide turndown

One dryer may run small development batches and full production batches. The fan is selected to stay stable across the full flow range, not just at maximum, so low flows do not push it into unstable operation.

Closed-cycle confusion

Specifying a supply fan for a closed nitrogen cycle duplicates the recirculation blower and adds a leak path. The cycle type is fixed first, and the fans are then chosen to match it.

Energy and control

Fan energy is small next to heating, dehumidification and, in closed cycle, solvent recovery. A variable speed drive suits the batch pattern and the cleaning cycle and lets the fan run slowly during warm-up. Dehumidifying the inlet air raises energy use but improves batch consistency, and is often required by the process.

ID fan and FD fan in pharmaceutical spray dryers

ID fanFD fan
PositionAfter the product and HEPA police filtersAfter pre-filters, before heater and HEPA
What it handlesMoist air or solvent-laden nitrogenClean filtered air (open cycle only)
Temperature at the fan50 to 90°C open cycle; cool in closed cycleRoom temperature
Main design concernGas-tightness and containmentRepeatable flow
ControlChamber pressure or loop flowGas flow

See also the Induced Draft (ID) Fan for pharmaceutical spray dryers.

Questions buyers ask

Does a closed-loop spray dryer have an FD fan?

Usually not a separate one. One recirculation blower drives the nitrogen round the loop through the chamber, filter, condenser and heater. Some large units use two blowers, but there is no ambient air supply.

Why is HEPA filtration after the heater?

So the air entering the chamber is free of particles from the duct, heater and fan. The supply fan therefore handles pre-filtered air, and the terminal HEPA filter protects the product.

How is gas flow controlled on a pharma spray dryer?

By a flow measurement and a variable speed drive on the supply or recirculation fan, with the setpoint fixed in the batch recipe so it is the same every batch.

Information needed to quote an FD fan for pharmaceutical spray dryers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Filtration and heating. Filter grades including HEPA, and heater type and pressure drop.
  6. Turndown. Lowest and highest gas flows the dryer will run.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for pharmaceutical spray dryers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote