Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Paddy Straw Fired Boilers

The FD fan on a paddy straw fired boiler supplies primary air under the vibrating or travelling grate, usually through a steam coil and a flue gas air heater. It handles ambient air, but the plant air is full of straw fibre, and the low ash melting point means primary air has to keep the grate and bed cool enough to stop clinker forming.

Send your duty pointCall +91 91766 67102
Ambient, 5 to 45°C over the year in north IndiaAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How paddy straw fired boilers work

Paddy straw is the stalk left after rice harvest. It is baled in the field and fired mainly in 10 to 30 MW biomass power plants and large industrial boilers in north India, where straw would otherwise be burnt in the open. Baled straw carries about 10 to 20% moisture, 12 to 18% ash and a calorific value of about 3,000 to 3,500 kcal/kg. The ash is mostly silica but rich in potassium, with chlorine often 0.3 to 0.8%, and it softens from about 800 to 900°C. Bales are broken and shredded, then fed onto a water-cooled vibrating grate or a travelling grate. The flue gas passes the superheaters, economiser and air heater, then an ESP or bag filter, before the ID fan.

Where the FD fan sits

  1. Inlet filter or screen
  2. FD fan
  3. Steam coil air heater
  4. Flue gas air heater
  5. Grate air plenum
  6. Vibrating grate

The FD fan sits at ground level near the air heaters. Many straw boilers use a steam coil air heater ahead of the flue gas air heater, so that the gas-side tube metal stays above the acid dew point. The air goes to compartments under the water-cooled vibrating grate, while a separate secondary air fan supplies the overfire nozzles. The FD fan works against both air heaters, the ducts, the dampers and the grate and bed, typically 150 to 250 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, 5 to 45°C over the year in north India
Air after the air heaters150 to 200°C, downstream of the fan
DustStraw fines and fibre in the boiler house air
Pressure at the fan outletTypically 150 to 250 mmWC
Ambient rangeWinter air is much denser than summer air, so mass flow at a fixed speed varies through the year
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for paddy straw fired boilers

Blade formBackward curved, for efficiency on filtered air
Material of constructionMild steel
Drive and arrangementDirect coupled, arrangement 8 or 4
Bearings and coolingStandard pedestal bearings; no cooling needed
Flow controlVariable speed drive on measured air flow, which corrects for ambient density
Also specifiedLow-velocity inlet filter or fine screen with a differential pressure gauge, and an inlet silencer

What this FD fan has to cope with

Straw fibre at the inlet

Bale handling throws light fibre into the air across the plant. Unfiltered, it mats on the inlet screen and impeller and on the steam coil fins, and the grate runs short of air. A generously sized filter or screen, an intake taken at height or away from the fuel shed, and a differential pressure alarm keep the airflow steady.

Clinker on the grate

Straw ash fuses at temperatures a poorly cooled bed reaches easily. Primary air cools the grate bars and limits bed temperature. The fan must deliver the air the grate maker specifies at every load, so the lowest useful flow is set by the minimum primary air for grate cooling, not by the lowest steam demand.

Seasonal change in air density

North Indian sites see air from near freezing in winter to above 40°C in summer. A fan sized for winter mass flow runs short in May; one sized for summer has surplus in January. Selecting at hot-weather density and controlling on measured mass flow covers the whole year.

Energy and control

Straw boilers run most of the year at steady output, so FD fan efficiency matters. A variable speed drive on measured air flow, with oxygen trim, removes damper losses and holds excess air near design as straw moisture changes between dry and damp bales. Lower excess air also cuts the gas volume the ID fans must handle, and that saving is usually larger than the FD fan saving itself.

ID fan and FD fan in paddy straw fired boilers

ID fanFD fan
PositionAfter the ESP or bag filterBefore the air heaters, feeding the grate
What it handlesFlue gas with silica and potassium chloride fumeAmbient air carrying straw fibre
Temperature at the fan140 to 160°C, up to 200°CAmbient, 5 to 45°C
Main design concernSalt deposits and corrosionClean intake and grate cooling air
ControlFurnace draftAir flow and excess oxygen

See also the Induced Draft (ID) Fan for paddy straw fired boilers.

Questions buyers ask

Does the FD fan on a straw fired boiler need an air filter?

In most straw plants, yes. Straw fines and fibre are everywhere around the fuel yard and boiler house. A low-velocity filter or fine screen at the forced draft fan inlet, cleaned regularly, stops fibre matting on the impeller and on the steam coil air heater fins.

How is air divided between the FD fan and the secondary air fan on a paddy straw boiler?

The FD fan delivers primary air up through the grate to the burning straw and keeps the grate cool. The secondary air fan blows air through nozzles in the furnace walls to burn the volatile gases released above the bed. Straw is highly volatile, so secondary air is a large share of the total.

Why do straw boilers use a steam coil air heater?

It warms the combustion air before the flue gas air heater, so the gas-side tube metal stays above the acid dew point and does not corrode. The FD fan pushes air through both heaters, so its pressure includes the steam coil resistance as well as the tubular air heater.

Information needed to quote an FD fan for paddy straw fired boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air heaters. Type of air heaters, steam coil and flue gas, and the air-side pressure drop of each.
  6. Site ambient. Minimum and maximum ambient temperature and the altitude of the plant.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for paddy straw fired boilers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.