Forced Draft (FD) Fan for Crude Distillation Unit Heaters

The FD fan on a crude distillation unit heater is the combustion air fan feeding the air preheater and then many burners across several cells. Its challenge is distributing air evenly to dozens of burners so that each pass gets uniform heat and the tubes do not overheat.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved or aerofoilBlade form

How crude distillation unit heaters work

The crude distillation unit heater takes desalted crude from the preheat train at about 250 to 290°C and heats it to 350 to 375°C at the column flash zone, partly vaporising it. It is usually the largest heater in the refinery, built as a box or cabin with several cells and multiple parallel passes, each pass with its own flow control. Refinery fuel gas and fuel oil, sometimes heavy residue, are fired. The convection section preheats crude and often generates or superheats steam. On a balanced draft design, flue gas from one or more cells is collected, passed through a large air preheater, and drawn to a stack by ID fans, while FD fans supply combustion air through the preheater to many burners.

Where the FD fan sits

  1. Inlet filter and silencer
  2. FD fans in parallel
  3. Air preheater, air side
  4. Hot air ducts to each cell
  5. Burner plenums
  6. Burners

The fans sit at grade beside the air preheater. They deliver cold air to the preheater, where it is heated to 220 to 300°C, and then through long insulated ducts to the burner plenums of each cell. Pressure needed is typically 120 to 250 mmWC, covering the preheater air side, the hot air ducts, cell dampers and burner registers. As on the flue side, two FD fans in parallel are common.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheater220 to 300°C
DustClean, filtered air
Pressure at the fan outletTypically 120 to 250 mmWC
TurndownFollowing crude throughput, 60 to 100% in normal operation
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for crude distillation unit heaters

Blade formBackward curved or aerofoil, double inlet for large flows
Material of constructionMild steel
Drive and arrangementDirect drive, double inlet
Bearings and coolingOil-lubricated bearings on large fans
Flow controlVariable speed drive on total air flow with oxygen trim; cell dampers for distribution
Also specifiedInlet silencer and filter, and API 673 or equivalent requirements

What this FD fan has to cope with

Uneven air between cells

Long hot air ducts to several cells give different pressure losses to each, so cells far from the fan run short of air while near cells run with excess. The heater then fires on the worst cell's oxygen. Duct design checked by flow modelling, cell dampers and an oxygen analyser on each cell keep firing even across the heater.

Pass temperature imbalance

Uneven air within a cell gives uneven flames and heat flux across the passes, so some passes run hot while others run cool, and the pass flow controllers fight to balance outlet temperatures. Enough fan pressure that the burner registers, not the ducts, are the main resistance, together with careful register setting, gives uniform heat flux.

Loss of an FD fan

With parallel fans, one fan trip must not cause a heater trip. Fast-closing outlet dampers on the tripped fan prevent air flowing backwards through it, and the running fan increases speed to carry the load. The running fan's motor and curve must cover this single-fan case, which is often the true sizing condition.

Energy and control

The crude heater's FD fans run all year and move a large air flow. Speed control on air flow with oxygen trim keeps excess air low across throughput changes. Improving air distribution between cells allows lower overall excess air, which is often worth more in fuel than any change to the fan itself.

ID fan and FD fan in crude distillation unit heaters

ID fanFD fan
PositionAfter the common air preheaterBefore the air preheater
What it handlesLarge flue gas flow, soot with fuel oilAmbient air
Temperature at the fan160 to 200°CAmbient
Main design concernSize, parallel operation and sootAir distribution across cells
ControlArch draft in each cellAir flow with oxygen trim

See also the Induced Draft (ID) Fan for crude distillation unit heaters.

Questions buyers ask

How is combustion air distributed in a multi-cell crude heater?

On a multi-cell crude heater the FD fans feed a common air preheater and then hot air ducts to each cell's burner plenum. Cell dampers and the individual burner registers set the distribution, guided by oxygen readings in each cell. Good duct design matters, because a combustion air fan can only supply pressure, not even distribution.

Why are two FD fans used on crude heaters?

Two forced draft fans in parallel provide redundancy, so the crude heater can continue at high load if one fan trips, and they allow maintenance on one fan without shutting down the crude unit. Each fan is sized for a large share of the total combustion air, often enough to hold most of the design throughput alone.

What happens if a crude heater FD fan fails?

With parallel fans, the other fan picks up the load, its speed rises and the heater may reduce firing slightly. With a single fan, the heater falls back to natural draft at reduced firing or trips. In either case the burner management system closes the tripped fan's damper to stop backflow of air through it.

Information needed to quote an FD fan for crude distillation unit heaters

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner count and layout. Number of burners per cell and the plenum arrangement.
  6. Parallel operation. Number of FD fans and the share of flow each must carry.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for crude distillation unit heaters: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.