13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Coal Gasifiers for Process Heat

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Coal Gasifiers for Process Heat

The FD fan on a coal gasifier is the gasification air blower. It pushes ambient air into the gasifier, where steam from the water jacket is added before the air enters the coal bed. The bed resistance changes as coal is charged and ash is removed, so pressure margin and protection against gas backflow decide its design.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How coal gasifiers for process heat work

Coal gasifiers for process heat convert lump coal into producer gas for ceramic kilns, glass furnaces, forging and heat treatment furnaces. Air, saturated with steam from the gasifier water jacket, is blown up through a fixed coal bed; the coal dries, devolatilises, then reacts to give a gas of typically 25 to 30% carbon monoxide, 10 to 15% hydrogen, some methane and about 50% nitrogen, with a heating value near 1,200 to 1,500 kcal/Nm³. In hot gas systems the gas goes straight to the burners at 400 to 600°C with its tar. In cold clean gas systems it passes a cyclone, cooler, scrubber and tar precipitator, and a gas booster draws it through this train and delivers it to the kiln burners.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Non-return valve
  4. Steam saturation
  5. Blast inlet
  6. Coal bed

The air blower sits at grade beside the gasifier and delivers air into the blast pipe, where steam from the water jacket or a saturator is mixed in. The mixture enters below the grate, then passes the ash, oxidation and reduction zones of the bed. The blower must overcome the grate, ash and coal bed resistance and, in hot gas systems, the gas main to the burners as well, typically 300 to 800 mmWC depending on bed depth and coal size.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Blast after saturation50 to 65°C saturated air and steam, downstream of the fan
DustCoal yard dust; inlet filtered
Pressure at the fan outletTypically 300 to 800 mmWC, varying with bed condition
Backflow riskProducer gas can flow back into the air line if the blower stops
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for coal gasifiers for process heat

Blade formBackward curved, with a steep pressure curve so flow holds as bed resistance changes
Material of constructionMild steel
Drive and arrangementDirect coupled
Bearings and coolingStandard pedestal or motor bearings
Flow controlVariable speed drive on gas demand, with an inlet damper
Also specifiedNon-return valve, explosion vent on the air line, and an interlock that closes the gas outlet on blower stop

What this FD fan has to cope with

Changing bed resistance

As coal is charged, fines settle, clinker forms and ash is withdrawn, the bed resistance moves up and down. A blower with a flat curve loses flow sharply when the bed tightens, and gas quality falls. A steep curve and control on gas pressure or flow keep the blast steady.

Gas backflow on blower stop

If the blower trips while the gasifier is hot, producer gas can flow back up the air line to the blower and building. A non-return valve, a vent on the blast pipe, and interlocks that act on blower failure are part of the fan package.

Channelling at low blast

At very low air flow the blast finds channels through the bed, burning holes and raising CO₂ in the gas. The turndown of the blower is limited to what the bed can tolerate, and low demand is met by reducing the number of gasifiers in service.

Energy and control

The blower follows kiln gas demand, and steam-to-air ratio must stay right as it does. A variable speed drive is preferred over damper throttling, because it also gives smoother control of bed temperature and gas quality. Where a plant runs several gasifiers, running fewer units near their design blast is usually more efficient for both the fans and the gasification than running all of them lightly loaded.

ID fan and FD fan in coal gasifiers for process heat

ID fanFD fan
PositionAfter the tar precipitator, before the gas mainAt grade, feeding the blast pipe
What it handlesCooled producer gas with tar tracesClean ambient air
Temperature at the fan35 to 50°CAmbient
Main design concernGas tightness and tar depositsBed resistance and backflow
ControlGas main pressureGas demand and steam ratio

See also the Induced Draft (ID) Fan for coal gasifiers for process heat.

Questions buyers ask

What is the air blower on a coal gasifier called?

It is usually called the gasification air blower, blast fan or FD fan. It forces air, mixed with steam, up through the coal bed. In a hot gas system it may be the only fan in the gas path. In a cold clean gas system it works alongside a gas booster.

What pressure does a coal gasifier air blower need?

Typically 300 to 800 mmWC, depending on bed depth, coal size, grate design and whether the blower also pushes the gas to the burners. Pressure margin is needed because bed resistance rises as fines and clinker build up. Hot gas systems need more, because the blower also pushes gas to the burners.

What happens if the gasifier blower stops?

Producer gas can flow back into the air line. The forced draft fan system needs a non-return valve, a blast pipe vent and interlocks that isolate the gas outlet, so a blower trip leaves the plant in a safe state. These are tested at every planned shutdown, not only at commissioning.

Information needed to quote an FD fan for coal gasifiers for process heat

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Gasifier data. Gasifier diameter, coal size and the bed depth at normal operation.
  6. System type. Whether the plant is a hot gas or cold clean gas system, and if a booster is installed.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for coal gasifiers for process heat: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote