Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Coal and Biomass Co-fired CFBC Boilers

On a coal and biomass co-fired CFBC boiler the FD fan is the primary air fan that fluidises the bed through the grid. It handles clean ambient air at high pressure. With more biomass, the furnace needs more secondary air higher up and less primary air, so the primary air fan must stay efficient as its share of the total air changes.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How coal and biomass co-fired CFBC boilers work

CFBC boilers are well suited to burning coal with a large share of biomass, from wood chips and bagasse to husk and agricultural residue, because the circulating hot solids even out the differences in fuel reactivity. Fuels are fed into the lower furnace and burn at 820 to 880°C, with solids carried up, separated in a hot cyclone and returned through a loop seal. Biomass shares of 30 to 70% by heat are common in captive and independent power plants. Alkali and chlorine from biomass raise the risk of agglomeration in the loop seal and of corrosive deposits on the superheaters. After the back pass and air heater the gas passes an ESP or bag filter and the ID fan.

Where the FD fan sits

  1. Inlet silencer
  2. FD (primary air) fan
  3. Air heater
  4. Air box
  5. Distribution grid
  6. Fluidised bed

The primary air fan sits at ground level and pushes ambient air through the air heater to the air box. A separate secondary air fan supplies air to ports higher in the furnace, where biomass volatiles burn. Loop seal blowers fluidise the cyclone return. PA fan outlet pressure is typically 1,000 to 1,500 mmWC. Some designs also use primary air to carry biomass into the furnace through feed chutes.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the air heater180 to 250°C, downstream of the fan
Pressure at the fan outletTypically 1,000 to 1,500 mmWC
Share of total airAbout 40 to 60% as primary air, falling as biomass share rises
DustClean air; biomass dust near the fuel yard
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for coal and biomass co-fired CFBC boilers

Blade formBackward curved, high pressure, with a stable characteristic over a wide flow range
Material of constructionMild steel throughout
Drive and arrangementDirect coupled, arrangement 8
Bearings and coolingPedestal bearings, oil lubricated on larger fans
Flow controlVariable speed drive with protected minimum fluidising flow
Also specifiedInlet silencer and screen; non-return dampers for parallel fans

What this FD fan has to cope with

Agglomeration in the bed and loop seal

Biomass alkalis form sticky compounds with bed sand, and agglomerates grow where fluidisation is weak, often in the loop seal or lower bed corners. The PA fan must hold fluidising air above the minimum at all loads and blends. Bed material refresh and bed temperature control are the other parts of the defence.

Changing PA share with fuel blend

On coal the boiler may run at 55 to 60% primary air; on high biomass, 40 to 45%. A PA fan selected only at the coal point may operate inefficiently or near its stall region on biomass. The selection is checked at both ends of the blend range.

Biomass fibre and dust at the intake

Biomass yards create fine dust and fibre. If the PA fan intake is near the yard, the material builds on the impeller and fouls the air heater. Taking air from a clean area and fitting a screen or filter with a regular cleaning schedule prevent this.

Energy and control

The primary air fan is one of the largest auxiliary loads in a co-fired CFBC plant. Its flow must stay above the fluidising minimum, so most turndown is taken by the secondary air fan. A variable speed drive on the PA fan, and bed inventory kept at design pressure, minimise the high pressure air it must supply. Checking fan power on each blend helps set the best operating split.

ID fan and FD fan in coal and biomass co-fired CFBC boilers

ID fanFD fan
PositionAfter the ESP or bag filterAhead of the air heater and grid
What it handlesFlue gas whose volume changes with blendClean ambient air
Temperature at the fan145 to 170°CAmbient, 25 to 45°C
Main design concernWide gas volume range across blendsStable fluidisation as PA share changes
ControlFurnace draftBed fluidisation, with SA taking turndown

See also the Induced Draft (ID) Fan for coal and biomass co-fired CFBC boilers.

Questions buyers ask

Why does the primary air share change when we fire more biomass?

Biomass releases most of its volatiles quickly and burns higher in the furnace than coal. More of the air is therefore supplied as secondary air above the dense bed, and less as primary air through the grid. The forced draft (PA) fan's duty point moves accordingly.

What is the FD fan on a co-fired CFBC boiler?

On most CFBC boilers the primary air fan is the FD fan, supplying fluidising air through the grid at high pressure. A separate secondary air fan supplies the upper furnace. Both are needed, and on a co-fired unit their split changes with the fuel blend.

Can biomass be fed with primary air on a CFBC?

Some designs use a share of primary air, or a dedicated sealing air fan, to carry biomass through feed chutes and prevent back-flow of hot gas. This takes air from the PA system and must be included in the fan duty. Check the boiler maker's feed system design.

Information needed to quote an FD fan for coal and biomass co-fired CFBC boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air split. Primary and secondary air flows for coal alone and for the highest biomass share.
  6. Bed. Design bed pressure and bed material refresh arrangement.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.