Forced Draft (FD) Fan for Carbon Anode Baking Furnaces

The FD fans on a carbon anode baking furnace are the blowing ramp fans that push ambient air into the flue walls of the cooling sections. The air cools the baked anodes and is preheated on its way to the fire, where it becomes combustion air. They handle ambient air and move with the fire.

Send your duty pointCall +91 91766 67102
Ambient, but warm above the furnace, 35 to 55°CAir temperature at the fan
1.09 kg/m³Air density at 50°C
Backward curvedBlade form

How carbon anode baking furnaces work

Carbon anodes for aluminium smelting are baked in open-top ring furnaces. Green anodes made of petroleum coke and coal tar pitch are packed in deep refractory pits, separated by hollow flue walls, and covered with packing coke. A fire of several sections moves slowly around the ring: burner ramps fire natural gas or fuel oil into the flues, pitch volatiles released from the anodes burn in the flues, and the anodes reach about 1,100 to 1,200°C. Blowing ramps push air into the cooling sections, where it is preheated by the baked anodes before reaching the fire. An exhaust ramp draws the flue gas into a ring main at 150 to 250°C and on to the fume treatment centre, then the ID fan.

Where the FD fan sits

  1. Inlet
  2. FD (blowing ramp) fan
  3. Blowing ramp manifold
  4. Flue walls in cooling sections
  5. Fire zone

Blowing ramp fans are mounted on portable ramps placed over the flue wall openings of the cooling sections, a few sections behind the fire. They push ambient air into the flues, where it is heated by the baked anodes before reaching the burner ramps. Each ramp is moved with the fire. Pressure required is moderate, typically 150 to 400 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, but warm above the furnace, 35 to 55°C
DustPacking coke and alumina dust over the furnace
Pressure at the fan outletTypically 150 to 400 mmWC
TurndownSteady, set by fire progression and cooling requirement
Density at the design temperatureAbout 1.09 kg/m³ at 50°C, 91% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for carbon anode baking furnaces

Blade formBackward curved, compact for portable ramps
Material of constructionMild steel
Drive and arrangementDirect mounted on the motor shaft for compact ramps
Bearings and coolingMotor bearings; motor rated for the hot furnace hall
Flow controlVariable speed drive on flow or flue pressure
Also specifiedInlet screen against packing coke dust, lifting points for crane handling

What this FD fan has to cope with

Hot, dusty furnace hall

Air above the furnace is warm and carries packing coke and alumina dust. The fan takes this air, which lowers its mass flow and builds dust on the impeller. Inlet screens and motors rated for the hall temperature keep the ramps reliable. Periodic cleaning restores flow.

Handling and damage

Blowing ramps are lifted and moved by crane at every fire move. Rough handling damages fans and connections. Robust frames, lifting points and flexible connections reduce damage. Fans that are light and compact for their duty make crane handling easier, and a simple electrical plug connection speeds the changeover at each fire move. Spare ramps allow a damaged fan to be repaired without delaying the fire.

Air distribution to the flues

Uneven air to the flue walls gives uneven cooling and combustion. Measured flow or pressure at each ramp, and fans with matched performance, keep the air distribution even. Poor distribution shows up as variation in anode baking level between pits, which affects smelter performance. Regular checks of flue pressure at each wall show where the air is uneven.

Energy and control

Blowing ramp fans run continuously as part of each fire. Speed control linked to flue pressure, rather than a fixed damper, matches air to the fire and saves power. The air they supply is preheated by the anodes, so the right amount of air also improves fuel economy and anode quality.

ID fan and FD fan in carbon anode baking furnaces

ID fanFD fan
PositionAfter the fume treatment centreOn portable ramps over the cooling sections
What it handlesTreated flue gas with tar and fluoride tracesWarm hall air
Temperature at the fan100 to 130°C35 to 55°C
Main design concernTar deposits and acid corrosionRobust portable design and even air
ControlRing main suctionFlue pressure at each ramp

See also the Induced Draft (ID) Fan for carbon anode baking furnaces.

Questions buyers ask

What is a blowing ramp on an anode baking furnace?

It is a portable manifold with fans that sits over the flue walls of the cooling sections and blows ambient air into them. The air cools the baked anodes and is preheated on its way to the fire zone, where it supports combustion. It is the forced draft side of the furnace.

Why do blowing ramp fan motors fail?

The air above the furnace is hot and dusty, and the ramps are moved often by crane. Motors in high ambient temperature, with dust and handling damage, fail early. Motors rated for the hall temperature, inlet screens and careful handling extend their life. Spare motors are usually kept.

Do blowing ramp fans handle hot gas?

No. They push ambient air into the flue walls. The air heats up downstream inside the furnace as it cools the anodes. The fans themselves see warm hall air, so mild steel construction is used. The motor is rated for the hall temperature, and the fan is sized for the reduced air density.

Information needed to quote an FD fan for carbon anode baking furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Ramp arrangement. Number of ramps per fire and flue walls per section.
  6. Air requirement. Air flow and pressure per flue wall.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for carbon anode baking furnaces: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.